Comparison of a polymer-based paclitaxel-eluting stent with a bare metal stent in patients with complex coronary artery disease: a randomized controlled trial.

JAMA 2005 September 15
CONTEXT: Compared with bare metal stents, drug-eluting stents reduce restenosis in noncomplex lesions. The utility of drug-eluting stents has not been evaluated in more difficult stenoses.

OBJECTIVE: To investigate the safety and efficacy of the polymer-based, slow-release paclitaxel-eluting stent in a patient population with more complex lesions than previously studied.

DESIGN, SETTING, AND PATIENTS: Prospective, placebo-controlled, double-blind, multicenter randomized trial conducted from February 2003 to March 2004 at 66 academic and community-based institutions with 1156 patients who underwent stent implantation in a single coronary artery stenosis (vessel diameter, 2.25-4.0 mm; lesion length, 10-46 mm), including 664 patients (57.4%) with complex or previously unstudied lesions (requiring 2.25-mm, 4.0-mm, and/or multiple stents) and 9-month clinical and angiographic follow-up.

INTERVENTIONS: Patients were randomly assigned to receive 1 or more bare metal stents (n = 579) or identical-appearing paclitaxel-eluting stents (n = 577).

MAIN OUTCOME MEASURE: Ischemia-driven target vessel revascularization at 9 months.

RESULTS: Baseline characteristics were well matched. Diabetes was present in 31% of patients. The mean (SD) reference vessel diameter was 2.69 (0.57) mm, the reference lesion length was 17.2 (9.2) mm, and 78% of lesions were type B2/C. A mean (SD) of 1.38 (0.58) stents (total mean [SD] length, 28.4 [13.1] mm) were implanted per lesion; 33% of lesions required multiple stents. Stents that were 2.25 mm and 4.0 mm in diameter were used in 18% and 17% of lesions, respectively. Compared with bare metal stents, paclitaxel-eluting stents reduced the 9-month rate of target lesion revascularization from 15.7% to 8.6% (P<.001) and target vessel revascularization from 17.3% to 12.1% (P = .02). Similar rates were observed for cardiac death or myocardial infarction (5.5% for bare metal stent group vs 5.7% for paclitaxel-eluting stent group) and stent thrombosis (0.7% in both groups). Angiographic restenosis was reduced from 33.9% to 18.9% in the entire study cohort (P<.001), including among patients receiving 2.25-mm stents (49.4% vs 31.2%; P = .01), 4.0-mm stents (14.4% vs 3.5%; P = .02), and multiple stents (57.8% vs 27.2%; P<.001).

CONCLUSION: Compared with a bare metal stent, implantation of the paclitaxel-eluting stent in a patient population with complex lesions effectively reduces clinical and angiographic restenosis.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app