Efficacy and safety of ipratropium bromide plus fenoterol inhaled via Respimat Soft Mist Inhaler vs. a conventional metered dose inhaler plus spacer in children with asthma.

The objective of this study was to compare the efficacy and safety of ipratropium bromide/fenoterol hydrobromide (IB/FEN; Berodual) delivered from the novel propellant-free Respimat Soft Mist Inhaler (SMI) with that from a chlorofluorocarbon (CFC) metered-dose inhaler (MDI) plus spacer in children with asthma. The study followed a multicenter, randomized, double-blind (within Respimat SMI), parallel-group design. During the 2-week run-in period, patients received two actuations of CFC-MDI tid (IB 20 microg/FEN 50 microg per actuation) via a spacer (Aerochamber) (MDI 40/100). Patients (n=535) were then randomized to: Respimat SMI containing IB 10 microg/FEN 25 microg (Respimat SMI 10/25), IB 20 microg/FEN 50 microg (Respimat SMI 20/50), one actuation tid or CFC-MDI containing IB 20 microg/FEN 50 microg per actuation (in total 1B 40 microg/FEN 100 microg), or two actuations tid via Aerochamber (MDI 40/100), for 4 weeks. The primary endpoint was the change in forced expiratory volume in 1 second (FEV1) during the first 60 min after dosing (area under the curve from 0-1 h [AUC(0-1 h)]) on day 29. Analysis of the primary endpoint demonstrated that the efficacy of Respimat SMI 10/25 and 20/50 was equivalent to or greater than that of MDI 40/100. Similar results indicating that Respimat SMI 10/25 and 20/50 were not inferior to MDI 40/100 were also found on days 1 and 15. Analyses of other secondary endpoints supported these results. The safety profile of Respimat SMI was comparable to that of the CFC-MDI plus spacer. In conclusion, IB/FEN delivered via Respimat SMI is at least as effective as, and is as safe as, when delivered via CFC-MDI plus Aerochamber in children with asthma. Use of Respimat SMI thus enables a 2-4-fold reduction in the nominal dose of IB/FEN, and obviates the need for a spacer.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app