Add like
Add dislike
Add to saved papers

Towards valid measures of self-directed clinical learning.

Medical Education 2003 November
AIM: To compare the validity of different measures of self-directed clinical learning.

METHODS: We used a quasi-experimental study design. The measures were: (1) a 23-item quantitative instrument measuring satisfaction with the learning process and environment; (2) free text responses to 2 open questions about the quality of students' learning experiences; (3) a quantitative, self-report measure of real patient learning, and (4) objective structured clinical examination (OSCE) and progress test results. Thirty-three students attached to a single firm during 1 curriculum year in Phase 2 of a problem-based medical curriculum formed an experimental group. Thirty-one students attached to the same firm in the previous year served as historical controls and 33 students attached to other firms within the same module served as contemporary controls. After the historical control period, experimental group students were exposed to a complex curriculum intervention that set out to maximise appropriate real patient learning through increased use of the outpatient setting, briefing and supported, reflective debriefing.

RESULTS: The quantitative satisfaction instrument was insensitive to the intervention. In contrast, the qualitative measure recorded a significantly increased number of positive statements about the appropriateness of real patient learning. Moreover, the quantitative self-report measure of real patient learning found high levels of appropriate learning activity. Regarding outpatient learning, the qualitative and quantitative real patient learning instruments were again concordant and changed in the expected direction, whereas the satisfaction measure did not. An incidental finding was that, despite all attempts to achieve horizontal integration through simultaneously providing community attachments and opening up the hospital for self-directed clinical learning, real patient learning was strongly bounded by the specialty interest of the hospital firm to which students were attached. Assessment results did not correlate with real patient learning.

CONCLUSIONS: Both free text responses and students' quantitative self-reports of real patient learning were more valid than a satisfaction instrument. One explanation is that students had no benchmark against which to rate their satisfaction and curriculum change altered their tacit benchmarks. Perhaps the stronger emphasis on self-directed learning demanded more of students and dissatisfied those who were less self-directed. Results of objective, standardised assessments were not sensitive to the level of self-directed, real patient learning. Despite an integrated curriculum design that set out to override disciplinary boundaries, students' learning remained strongly influenced by the specialty of their hospital firm.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app