Outcomes 15 years after valve replacement with a mechanical versus a bioprosthetic valve: final report of the Veterans Affairs randomized trial.

OBJECTIVES: The goal of this study was to compare long-term survival and valve-related complications between bioprosthetic and mechanical heart valves.

BACKGROUND: Different heart valves may have different patient outcomes.

METHODS: Five hundred seventy-five patients undergoing single aortic valve replacement (AVR) or mitral valve replacement (MVR) at 13 VA medical centers were randomized to receive a bioprosthetic or mechanical valve.

RESULTS: By survival analysis at 15 years, all-cause mortality after AVR was lower with the mechanical valve versus bioprosthesis (66% vs. 79%, p = 0.02) but not after MVR. Primary valve failure occurred mainly in patients <65 years of age (bioprosthesis vs. mechanical, 26% vs. 0%, p < 0.001 for AVR and 44% vs. 4%, p = 0.0001 for MVR), and in patients > or =65 years after AVR, primary valve failure in bioprosthesis versus mechanical valve was 9 +/- 6% versus 0%, p = 0.16. Reoperation was significantly higher for bioprosthetic AVR (p = 0.004). Bleeding occurred more frequently in patients with mechanical valve. There were no statistically significant differences for other complications, including thromboembolism and all valve-related complications between the two randomized groups.

CONCLUSIONS: At 15 years, patients undergoing AVR had a better survival with a mechanical valve than with a bioprosthetic valve, largely because primary valve failure was virtually absent with mechanical valve. Primary valve failure was greater with bioprosthesis, both for AVR and MVR, and occurred at a much higher rate in those aged <65 years; in those aged > or =65 years, primary valve failure after AVR was not significantly different between bioprosthesis and mechanical valve. Reoperation was more common for AVR with bioprosthesis. Thromboembolism rates were similar in the two valve prostheses, but bleeding was more common with a mechanical valve.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Group 7SearchHeart failure treatmentPapersTopicsCollectionsEffects of Sodium-Glucose Cotransporter 2 Inhibitors for the Treatment of Patients With Heart Failure Importance: Only 1 class of glucose-lowering agents-sodium-glucose cotransporter 2 (SGLT2) inhibitors-has been reported to decrease the risk of cardiovascular events primarily by reducingSeptember 1, 2017: JAMA CardiologyAssociations of albuminuria in patients with chronic heart failure: findings in the ALiskiren Observation of heart Failure Treatment study.CONCLUSIONS: Increased UACR is common in patients with heart failure, including non-diabetics. Urinary albumin creatininineJul, 2011: European Journal of Heart FailureRandomized Controlled TrialEffects of Liraglutide on Clinical Stability Among Patients With Advanced Heart Failure and Reduced Ejection Fraction: A Randomized Clinical Trial.Review

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app