keyword
https://read.qxmd.com/read/37555034/an-analytical-mathematical-annuloplasty-ring-curvature-model-for-planning-of-valve-in-ring-transcatheter-mitral-valve-replacement
#1
JOURNAL ARTICLE
Matthew H Park, Mateo Marin-Cuartas, Mark Sellke, Pearly K Pandya, Yuanjia Zhu, Robert J Wilkerson, David M Holzhey, Michael A Borger, Y Joseph Woo
OBJECTIVES: An increasing number of high-risk patients with previous mitral valve annuloplasty require transcatheter mitral valve replacement due to recurrent regurgitation. Annulus dilation with a transcatheter balloon is often performed before valve-in-ring transcatheter mitral valve replacement, which is believed to reduce misalignment and paravalvular leakage, yet little evidence exists to support this practice. Our objective was to generate intuitive annuloplasty ring analyses for improved valve-in-ring transcatheter mitral valve replacement planning...
August 2023: JTCVS techniques
https://read.qxmd.com/read/35060183/a-case-of-double-chambered-right-ventricle-due-to-cap-like-fibrous-tissue-and-aberrant-chordal-insertion-of-tricuspid-valve-in-adult
#2
Risa Shimbori, Masaaki Koide, Minori Tateishi, Yoshifumi Kunii, Satoshi Okugi
BACKGROUND: A double-chambered right ventricle is a rare congenital heart disease where an anomalous structure divides the right ventricle into two cavities. CASE: A 78-year-old man with dyspnea was referred to our institution for a double-chambered right ventricle (DCRV) and ventricular septal defect (VSD). Echocardiography showed normal left ventricular function, right ventricular hypertrophy, and mild tricuspid regurgitation. On parasternal short-axis views, color-flow Doppler studies showed a mosaic pattern through the stenotic right ventricular outflow tract (RVOT)...
April 2022: Journal of Cardiac Surgery
https://read.qxmd.com/read/33601467/clinical-outcomes-after-mitral-valve-repair-with-the-physio-ii-annuloplasty-ring
#3
JOURNAL ARTICLE
Thilo Noack, Franz Sieg, Mateo Marin Cuartas, Ricardo Spampinato, David Holzhey, Joerg Seeburger, Michael Andrew Borger
BACKGROUND:  Mitral valve (MV) repair with annuloplasty is the standard of care in patients with primary degenerative mitral regurgitation (DMR). Newer generations of annuloplasty rings have been developed with the goals of closer reproduction of native annular geometry and easier implantation. This study investigates the short-term and 5-year clinical outcomes of MV repair with the Carpentier-Edwards (CE) Physio II annuloplasty ring. METHODS:  This is an observational study including a total of 486 patients who underwent MV repair for DMR using the CE Physio II annuloplasty ring between 2011 and 2016...
February 18, 2021: Thoracic and Cardiovascular Surgeon
https://read.qxmd.com/read/33154921/the-carpentier-edwards-classic-and-physio-annuloplasty-rings-in-repair-of-degenerative-mitral-valve-disease-a-retrospective-study
#4
JOURNAL ARTICLE
Abubakari I Sidiki, Alexandr G Faybushevich, Alexandr N Lishchuk, Alexandr N Koltunov, Ekaterina A Roshchina
BACKGROUND: Physio ring (SR) is considered an improved version of the Classic rigid ring (RR). Today, SR is more widely used in mitral valve (MV) repair. We sought to compare the long-term outcomes of repair with RR and SR in degenerative mitral valve disease. METHODS: In a computerized registry of our institution, 306 patients had MV repair with either RR (139 patients) or SR (167 patients) ring between 2005 and 2015. Fifteen of them had concomitant tricuspid valve repair...
2020: Journal of the Saudi Heart Association
https://read.qxmd.com/read/31196216/mitral-valve-repair-moving-towards-a-personalized-ring
#5
JOURNAL ARTICLE
Antonios Pitsis, Timotheos Kelpis, Efstratios Theofilogiannakos, Nikolaos Tsotsolis, Harisios Boudoulas, Konstantinos Dean Boudoulas
BACKGROUND: Mitral valve repair with the use of an annuloplasty ring is the procedure of choice in patients with significant mitral regurgitation (MR) due to floppy mitral valve (FMV)/mitral valve prolapse (MVP). The mitral annular size, shape and motion may vary substantially among patients and thus, commercially available rings may not be suitable for each individual patient. METHODS: A "personalized ring" (PR) was easily constructed in the operating room using a Dacron sheet and titanium ligating clips to custom fit to each individual mitral annulus shape and size...
June 13, 2019: Journal of Cardiothoracic Surgery
https://read.qxmd.com/read/30803776/do-annuloplasty-rings-designed-to-treat-ischemic-functional-mitral-regurgitation-alter-left-ventricular-dimensions-in-the-acutely-ischemic-ovine-heart
#6
JOURNAL ARTICLE
Wolfgang Bothe, John Peder Escobar Kvitting, Manuel K Rausch, Tomasz A Timek, Julia C Swanson, David H Liang, Mario Walther, Ellen Kuhl, Neil B Ingels, D Craig Miller
OBJECTIVE: To quantify the effects of annuloplasty rings designed to treat ischemic/functional mitral regurgitation on left ventricular septal-lateral (S-L) and commissure-commissure (C-C) dimensions. METHODS: Radiopaque markers were placed as opposing pairs on the S-L and C-C aspects of the mitral annulus and the basal, equatorial, and apical level of the left ventricle (LV) in 30 sheep. Ten true-sized Carpentier-Edwards Physio (PHY), Edwards IMR ETlogix (ETL), and GeoForm (GEO; all from Edwards Lifesciences, Irvine, Calif) annuloplasty rings were inserted in a releasable fashion...
October 2019: Journal of Thoracic and Cardiovascular Surgery
https://read.qxmd.com/read/30770923/comparison-of-the-sustainability-of-mitral-annular-dynamics-between-two-semi-rigid-annuloplasty-devices
#7
JOURNAL ARTICLE
Stefaan Bouchez, Frank Timmermans, Tine Philipsen, Katrien François, Thierry Bové
OBJECTIVES: The choice of annuloplasty device is fundamental at the time of mitral valve repair, the goal being to optimally restore the physiological 3-dimensional (3D) structure and dynamics of the mitral annulus (MA). This study evaluated MA dynamics after annuloplasty with 2 different semi-rigid devices. METHODS: Thirty-three patients eligible for mitral valve repair were selected for annuloplasty with the Physio II ring (Edwards Lifesciences, Irving, CA, USA) (n = 17) or the Memo 3D ring (LivaNova, Saluggia, Italy) (n = 16)...
February 15, 2019: European Journal of Cardio-thoracic Surgery
https://read.qxmd.com/read/28728784/mitral-annuloplasty-ring-suture-forces-impact-of-surgeon-ring-and-use-conditions
#8
JOURNAL ARTICLE
Eric L Pierce, Charles H Bloodworth, Andrew W Siefert, Thomas F Easley, Tetsushi Takayama, Tomonori Kawamura, Robert C Gorman, Joseph H Gorman, Ajit P Yoganathan
OBJECTIVE: The study objective was to quantify the effect of ring type, ring-annulus sizing, suture position, and surgeon on the forces required to tie down and constrain a mitral annuloplasty ring to a beating heart. METHODS: Physio (Edwards Lifesciences, Irvine, Calif) or Profile 3D (Medtronic, Dublin, Ireland) annuloplasty rings were instrumented with suture force transducers and implanted in ovine subjects (N = 23). Tie-down forces and cyclic contractile forces were recorded and analyzed at 10 suture positions and at 3 levels of increasing peak left ventricular pressure...
January 2018: Journal of Thoracic and Cardiovascular Surgery
https://read.qxmd.com/read/28329364/the-effect-of-different-mitral-annuloplasty-rings-on-valve-geometry-and-annular-stress-distribution%C3%A2
#9
JOURNAL ARTICLE
Søren Nielsen Skov, Diana Mathilde Røpcke, Marcell Juan Tjørnild, Christine Ilkjær, Jonas Rasmussen, Hans Nygaard, Morten Olgaard Jensen, Sten Lyager Nielsen
OBJECTIVES: To characterize the remodelling effects and deformational forces of normosized rigid, semirigid and flexible mitral annuloplasty rings after implantation in healthy pigs. METHODS: Measurements were performed in vivo with 80-kg porcine animals. Twenty-eight animals were randomized into a no ring group, a flexible ring group (Duran AnCore Ring, Medtronic, Minneapolis, MN, USA), a rigid ring group (Carpentier-Edwards Classic annuloplasty ring, Edwards Lifesciences, Irvine, CA, USA) and a semirigid ring group (Carpentier-Edwards Physio I annuloplasty ring, Edwards Lifesciences)...
May 1, 2017: Interactive Cardiovascular and Thoracic Surgery
https://read.qxmd.com/read/28297697/evaluation-of-infection-resistance-of-biodegradable-versus-conventional-annuloplasty-rings-in-an-in-vivo-rat-subcutaneous-model
#10
COMPARATIVE STUDY
Ilhan Ozgol, Burak Can Depboylu, Aybala Tongut, Sinem Ozdemir, Yasar Bagdatlı, Sanaz Ainechi, Buge Oz, Jean-Claude Pache, Selim Erenturk, Afksendiyos Kalangos, Ali Can Hatemi, Mustafa Cikirikcioglu
BACKGROUND: Biodegradable atrioventricular annuloplasty rings are theoretically more infection resistant due to their intra-annular implantation technique and nonporous structures (monofilament of poly-1,4-dioxanone). The aim of this study was to investigate the infection resistance of a biodegradable annuloplasty ring (Kalangos-Bioring®) in a rat subcutaneous implantation model and to compare it with a commonly used conventional annuloplasty ring (Edwards Physio II®). METHODS: This study included 32 Wistar albino rats which were divided into 2 groups according to the implantation of sterile or infected annuloplasty rings as control and study groups...
2017: European Surgical Research. Europäische Chirurgische Forschung. Recherches Chirurgicales Européennes
https://read.qxmd.com/read/28175268/semi-rigid-mitral-annuloplasty-rings-improve-myocardial-stress-adaptation-compared-to-rigid-rings-insights-from-in-vitro-and-in-vivo-experimental-evaluation
#11
JOURNAL ARTICLE
Søren Nielsen Skov, Diana Mathilde Røpcke, Marcell Juan Tjørnild, Christine Ilkjær, Jonas Rasmussen, Hans Nygaard, Morten Olgaard Jensen, Sten Lyager Nielsen
OBJECTIVES: Investigate myocardial stress adaptation and remodelling capacity of a rigid and semi-rigid mitral annuloplasty ring. METHODS: The annuloplasty rings were characterized in vitro in a mechanical setup with tensile and compressive forces from 0 to 3 N. The rings were tested with and without fixation of the ring to imitate the effect of annular implantation. In vivo measurements were performed with 21 porcine animals randomized into: A no ring group, a rigid ring group (Classic Annuloplasty Ring TM , Edwards Lifesciences) and a semi-rigid ring group (Physio I Annuloplasty Ring, Edwards Lifesciences)...
May 1, 2017: European Journal of Cardio-thoracic Surgery
https://read.qxmd.com/read/26687280/annular-dynamics-after-mitral-valve-repair-with-different-prosthetic-rings-a-real-time-three-dimensional-transesophageal-echocardiography-study
#12
JOURNAL ARTICLE
Hiroyuki Nishi, Koichi Toda, Shigeru Miyagawa, Yasushi Yoshikawa, Satsuki Fukushima, Masashi Kawamura, Daisuke Yoshioka, Tetsuya Saito, Takayoshi Ueno, Toru Kuratani, Yoshiki Sawa
PURPOSE: We assessed the effects of different types of prosthetic rings on mitral annular dynamics using real-time three-dimensional echocardiography (RT3DE). METHODS: RT3DE was performed in 44 patients, including patients undergoing mitral annuloplasty using the Cosgrove-Edwards flexible band (Group A, n = 10), the semi-rigid Sorin Memo 3D ring (Group B, n = 17), the semi-rigid Edwards Physio II ring (Group C, n = 7) and ten control subjects...
September 2016: Surgery Today
https://read.qxmd.com/read/24996707/suture-forces-in-undersized-mitral-annuloplasty-novel-device-and-measurements
#13
JOURNAL ARTICLE
Andrew W Siefert, Eric L Pierce, Madonna Lee, Morten Ø Jensen, Chikashi Aoki, Satoshi Takebayashi, Joan Fernandez Esmerats, Robert C Gorman, Joseph H Gorman, Ajit P Yoganathan
PURPOSE: To demonstrate the first use of a novel technology for quantifying suture forces on annuloplasty rings to better understand the mechanisms of ring dehiscence. DESCRIPTION: Force transducers were developed, attached to a size 24 Physio ring, and implanted in the mitral annulus of an ovine animal. Ring suture forces were measured after implantation and for cardiac cycles reaching peak left ventricular pressures (LVP) of 100, 125, and 150 mm Hg. EVALUATION: After implantation of the undersized ring to the flaccid annulus, the mean suture force was 2...
July 2014: Annals of Thoracic Surgery
https://read.qxmd.com/read/23566678/comparison-of-the-novel-medtentia-double-helix-mitral-annuloplasty-system-with-the-carpentier-edwards-physio-annuloplasty-ring-morphological-and-functional-long-term-outcome-in-a-mitral-valve-insufficiency-sheep-model
#14
COMPARATIVE STUDY
Moritz A Konerding, Jarmo Simpanen, Leo Ihlberg, Juha Aittomäki, Kalervo Werkkala, Vera Delventhal, Maximilian Ackermann
BACKGROUND: The prevalence of mitral regurgitation in cardiac diseases requires annuloplasty systems that can be implanted without excessive patient burden. This study was designed to examine the morphological and functional outcome of a new double helix mitral annuloplasty ring in an ovine model in comparison to the classical Carpentier-Edwards (CE) annuloplasty ring as measured by reduction of mitral regurgitation and tissue integration. The Medtentia annuloplasty ring (MAR) is a helical device that is rotated into the annulus self-restoring the valve geometry, enabling a faster fixation without the need of elaborate repair of the valve geometry...
2013: Journal of Cardiothoracic Surgery
https://read.qxmd.com/read/22351705/the-influence-of-saddle-shaped-annuloplasty-on-leaflet-curvature-in-patients-with-ischaemic-mitral-regurgitation
#15
COMPARATIVE STUDY
Mathieu Vergnat, Melissa M Levack, Arminder S Jassar, Benjamin M Jackson, Michael A Acker, Y Joseph Woo, Robert C Gorman, Joseph H Gorman
OBJECTIVES: Reports indicate that repair procedures for ischaemic mitral regurgitation (IMR) are less durable than previously thought. Repair failure has been shown to be stress related. Leaflet curvature is the major determinant of valve stress. Theoretical and animal experiments have shown that saddle-shaped annuloplasty optimizes leaflet curvature when compared with standard flat ring annuloplasty. Despite this, the influence of the ring shape on leaflet curvature has not been described in patients with IMR...
September 2012: European Journal of Cardio-thoracic Surgery
https://read.qxmd.com/read/22050989/pseudoprolapse-of-the-anterior-leaflet-in-chronic-ischemic-mitral-regurgitation-identification-and-repair
#16
JOURNAL ARTICLE
Sabet W Hashim, Samuel J Youssef, Bassem Ayyash, Anthony J Rousou, Sigurdur Ragnarsson, Susan Collazo, Arnar Geirsson
OBJECTIVE: Recurrence rates as high as 30% have been observed 6 months after treatment of chronic ischemic mitral regurgitation (CIMR) with isolated annuloplasty. We postulated that the high early recurrence rates resulted from the presence of untreated pseudoprolapse of the anterior leaflet. METHODS: We conducted a retrospective study of all mitral valve repairs for CIMR performed by a single surgeon (S.W.H.) from 1995 to 2011. After annuloplasty, Gore-Tex neochordae were added if the high-pressure saline test indicated the presence of pseudoprolapse of the anterior leaflet...
April 2012: Journal of Thoracic and Cardiovascular Surgery
https://read.qxmd.com/read/21842677/-mitral-regurgitation-with-concomitant-atrial-septal-aneurysm-report-of-a-case
#17
JOURNAL ARTICLE
Hideaki Mori, Hiroki Hayashi, Yasushi Matsushita
A 64-year-old female was admitted to our hospital because of severe dyspnea. Echocardiography revealed mitral valve regurgitation and atrial septal aneurysm (ASA). After instituting medical treatment for congestive heart failure, euvolemic status was achieved, and the patient underwent; (1) prosthetic patch repair for ASA; (2) mitral valvuloplasty with partial quadrangular resection of the posterior mitral leaflet; and (3) mitral annuloplasty using Physio ring. Pathological examination revealed myxomatous degeneration of the mitral valve, but the resected atrial septum was without any abnormality...
August 2011: Kyobu Geka. the Japanese Journal of Thoracic Surgery
https://read.qxmd.com/read/21241857/effects-of-different-annuloplasty-ring-types-on-mitral-leaflet-tenting-area-during-acute-myocardial-ischemia
#18
COMPARATIVE STUDY
Wolfgang Bothe, John-Peder Escobar Kvitting, Elizabeth H Stephens, Julia C Swanson, David H Liang, Neil B Ingels, D Craig Miller
OBJECTIVE: The study objective was to quantify the effects of different annuloplasty rings on mitral leaflet septal-lateral tenting areas during acute myocardial ischemia. METHODS: Radiopaque markers were implanted along the central septal-lateral meridian of the mitral valve in 30 sheep: 1 each to the septal and lateral aspects of the mitral annulus and 4 and 2 along the anterior and posterior mitral leaflets, respectively. Ten true-sized Carpentier-Edwards Physio, Edwards IMR ETLogix, and GeoForm annuloplasty rings (Edwards Lifesciences, Irvine, Calif) were inserted in a releasable fashion...
February 2011: Journal of Thoracic and Cardiovascular Surgery
https://read.qxmd.com/read/21106384/initial-experience-of-mitral-valve-repair-using-the-carpentier-edwards-physio-ii-annuloplasty-ring
#19
JOURNAL ARTICLE
Hunaid A Vohra, Robert N Whistance, Laurynas Bezuska, Steve A Livesey
OBJECTIVE: The Carpentier-Edwards (CE) Physio II ring is a new prosthetic ring designed to accommodate the changing pathology seen in the spectrum of degenerative valve disease, particularly the larger anterior leaflet in repair of the Barlow valve. The aim of our study was to assess the safety and efficacy of mitral valve (MV) repair with the CE Physio II ring. METHODS: Between April 2009 and March 2010, 100 patients underwent MV repair using the Physio II ring...
June 2011: European Journal of Cardio-thoracic Surgery
https://read.qxmd.com/read/21042057/response-of-two-annular-prostheses-to-functional-mitral-regurgitation-main-determinants-an-in-vitro-evaluation
#20
COMPARATIVE STUDY
Emiliano Votta, Riccardo Vismara, Alberto Redaelli, Lorenzo Arcobasso, Francesco Maisano, Ottavio Alfieri, Gianfranco B Fiore
Functional mitral regurgitation (FMR) is usually treated through annuloplasty, i.e., the restriction of the mitral annulus by implanting an undersized prosthetic ring. We conceived a steady-state fluid-dynamic mock simulator that allows for controlling the main mechanic determinants of FMR: transmitral pressure and papillary muscle (PM) apical and lateral dislocation. We used our system to compare the FMR-specific Geoform ring with the general purpose Physio ring in the treatment of FMR. Each ring was implanted on 10 excised fresh porcine valves...
November 2010: ASAIO Journal: a Peer-reviewed Journal of the American Society for Artificial Internal Organs
keyword
keyword
169499
1
2
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.