We have located links that may give you full text access.
Comparative Study
English Abstract
Journal Article
[The diagnostic value of the rate-corrected QT interval in long-term type-1 diabetes mellitus].
Deutsche Medizinische Wochenschrift 1996 June 22
OBJECTIVE: To assess the relationship between rate-corrected QT interval (QTc interval) and cardiac reflex tests in order to determine the value of QTc interval measurements in the diagnosis of diabetic cardiac autonomic neuropathy.
INVESTIGATIONS: The QTc interval was measured in the resting ECG of 97 type 1 diabetics (58 women, 39 men; mean age 35 +/- 12 years; duration of diabetes 18 +/- 10 years; HbA1c 7.8 +/- 1.8%). Age-related results were compared with five cardiac function tests (heart rate variation at rest and on forced breathing; 30/15 ratio of heart rate; Valsalva manoeuvre; orthostasis).
RESULTS: The QTc interval was not prolonged ( < or = 440 ms) in 68 patients (70%), while in 29 (30%) it was prolonged ( > 440 ms). No significant differences regarding QTc interval were found between patients with autonomic cardiac neuropathy ( > or = 2 abnormal function tests) and those without ( < 2 abnormal function tests) (QTc interval 436 +/- 25 vs 426 +/- 19 ms). QTc intervals correlated with the coefficients of variation for heart rate variation at rest and on forced breathing and the 30/15 ratio of heart rate (p = 0.001; p = 0.001; p = 0.03), but not with the results of the Valsalva manoeuvre and the orthostasis test.
CONCLUSION: Prolongation of the QTc interval in longstanding type 1 diabetes does not provide a reliable indication of cardiac autonomic neuropathy and this measure cannot replace conventional reflex tests for its diagnosis.
INVESTIGATIONS: The QTc interval was measured in the resting ECG of 97 type 1 diabetics (58 women, 39 men; mean age 35 +/- 12 years; duration of diabetes 18 +/- 10 years; HbA1c 7.8 +/- 1.8%). Age-related results were compared with five cardiac function tests (heart rate variation at rest and on forced breathing; 30/15 ratio of heart rate; Valsalva manoeuvre; orthostasis).
RESULTS: The QTc interval was not prolonged ( < or = 440 ms) in 68 patients (70%), while in 29 (30%) it was prolonged ( > 440 ms). No significant differences regarding QTc interval were found between patients with autonomic cardiac neuropathy ( > or = 2 abnormal function tests) and those without ( < 2 abnormal function tests) (QTc interval 436 +/- 25 vs 426 +/- 19 ms). QTc intervals correlated with the coefficients of variation for heart rate variation at rest and on forced breathing and the 30/15 ratio of heart rate (p = 0.001; p = 0.001; p = 0.03), but not with the results of the Valsalva manoeuvre and the orthostasis test.
CONCLUSION: Prolongation of the QTc interval in longstanding type 1 diabetes does not provide a reliable indication of cardiac autonomic neuropathy and this measure cannot replace conventional reflex tests for its diagnosis.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app