N-95/P2 respirator compliance with fit testing recommendations and respirator satisfaction amongst hospital staff.

BACKGROUND: Filtering Facepiece Respirators (FFRs) are an important and readily scalable infection control measure; however their effectiveness is ultimately determined by compliance. We aimed to examine staff compliance and satisfaction with wearing the N95/P2 FFRs assigned to them via the standardised fit testing protocol implemented in a single large healthcare network in Victoria, Australia.

METHODS: In this cross-sectional survey, employees from five hospital campuses who participated in the health networks N95/P2 FFR fit testing process were invited in person to participate in the study. Data were analysed descriptively, after which chi-squared analysis was performed to determine differences between respirator types, gender, and age groups.

RESULTS: Amongst the 258 staff members surveyed, 28% had either never or only sometimes worn an FFR to which they had been successfully fit tested, and 11% had experienced facial changes that potentially rendered their most recent fit test invalid. More than half (53%) of those surveyed had experienced side effects, the most common being skin irritation and pressure sores. A majority (87%) of staff felt that wearing an FFR had some impact on their ability to perform their duties. Pooled mean self-reported satisfaction ratings were highest for three-panel flat-fold and duckbill models.

CONCLUSION: 28% of HCWs surveyed described not wearing N-95/P2 FFRs for which they had successfully been fit tested. Reasons for non-compliance remain unclear, but rates of side effects and interference with duties were high. Further research is required to determine and address potential causative factors and ascertain ongoing optimal organisation-level fit test strategies.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app