Emergency Physician Performed Ultrasound-Guided Abdominal Paracentesis: A Retrospective Analysis.

POCUS J 2024
BACKGROUND: Emergency physicians commonly perform ultrasound-assisted abdominal paracentesis, using point of care ultrasound (POCUS) to identify ascites and select a site for needle insertion. However, ultrasound-guided paracentesis has the benefit of real-time needle visualization during the entire procedure. Our objective was to characterize the performance of emergency physician-performed ultrasound-guided paracentesis using POCUS, their ability to achieve good in-plane needle visualization, and factors associated with procedural success.

METHODS: A POCUS database was retrospectively reviewed for examinations where abdominal paracentesis was performed by an emergency physician at two academic urban emergency departments over a six-year period. Medical records were reviewed for demographics, presenting history, complications, and hospital course. Descriptive statistics were used to summarize the data.

RESULTS: 131 patients were included in the final analysis. The success rate for ultrasound-guided paracentesis was 97.7% (84/86 [95% CI: 92-100%]) compared to 95.6% (43/45 [95% CI: 85-99%]) for ultrasound-assisted paracentesis (p=0.503). 58% (50/86) demonstrated good in-plane needle visualization; 17% (15/86) had partial or out-of-plane visualization; and 24% (21/86) did not demonstrate needle visibility on their saved POCUS images. All four procedural failures were performed by first- or second-year residents using a curvilinear transducer, while all procedures using a linear transducer were successful. The most common complications were ascites leak, infection at the site, and minor bleeding.

CONCLUSIONS: Emergency physicians with training in real-time needle guidance with ultrasound were able to use POCUS to perform ultrasound-guided paracentesis in the emergency department with a high success rate and no fatal complications. Based on our experience, we recommend performing ultrasound-guided paracentesis using a linear transducer, with attention to identifying vessels near the procedure site and maintaining sterile technique.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app