Add like
Add dislike
Add to saved papers

Distraction-aware hierarchical learning for vascular structure segmentation in intravascular ultrasound images.

Vascular structure segmentation in intravascular ultrasound (IVUS) images plays an important role in pre-procedural evaluation of percutaneous coronary intervention (PCI). However, vascular structure segmentation in IVUS images has the challenge of structure-dependent distractions. Structure-dependent distractions are categorized into two cases, structural intrinsic distractions and inter-structural distractions. Traditional machine learning methods often rely solely on low-level features, overlooking high-level features. This way limits the generalization of these methods. The existing semantic segmentation methods integrate low-level and high-level features to enhance generalization performance. But these methods also introduce additional interference, which is harmful to solving structural intrinsic distractions. Distraction cue methods attempt to address structural intrinsic distractions by removing interference from the features through a unique decoder. However, they tend to overlook the problem of inter-structural distractions. In this paper, we propose distraction-aware hierarchical learning (DHL) for vascular structure segmentation in IVUS images. Inspired by distraction cue methods for removing interference in a decoder, the DHL is designed as a hierarchical decoder that gradually removes structure-dependent distractions. The DHL includes global perception process, distraction perception process and structural perception process. The global perception process and distraction perception process remove structural intrinsic distractions then the structural perception process removes inter-structural distractions. In the global perception process, the DHL searches for the coarse structural region of the vascular structures on the slice of IVUS sequence. In the distraction perception process, the DHL progressively refines the coarse structural region of the vascular structures to remove structural distractions. In the structural perception process, the DHL detects regions of inter-structural distractions in fused structure features then separates them. Extensive experiments on 361 subjects show that the DHL is effective (e.g., the average Dice is greater than 0.95), and superior to ten state-of-the-art IVUS vascular structure segmentation methods.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app