Technical challenges during emergent endovascular aneurysm repair with the ALTO system.
Expert Review of Medical Devices 2024 April 4
INTRODUCTION: Ruptured abdominal aortic aneurysms (AAAs) pose an immediate threat for patient's life and endovascular repair (EVAR) is currently the preferred treatment modality in the presence of suitable anatomy. This is determined based on the requirements of each endograft as described in the instructions for use (IFU). The new ALTO system (Endologix, Irvin, CA, U.S.A.), can accommodate a great range of anatomies such as short necks and/or narrow access, but its unique design requires specific technical modifications during treatment of ruptured AAAs.
AREAS COVERED: The standard double balloon technique has long been described and it is used to provide circulatory support during EVAR for ruptured AAA. While this technique is straightforward with the use of endografts with a traditional design, this would not be the case if one uses the ALTO system. In that case specific maneuvers would be required to treat AAA patients in an acute setting.
EXPERT OPINION: The ALTO system although being able to treat AAAs with adverse anatomy, it may not be appropriate during treatment of ruptured AAA patients with profound hemodynamic instability. A careful evaluation of the individual's patient anatomy and hemodynamic condition is mandatory in order to decide the best endograft for each case.
AREAS COVERED: The standard double balloon technique has long been described and it is used to provide circulatory support during EVAR for ruptured AAA. While this technique is straightforward with the use of endografts with a traditional design, this would not be the case if one uses the ALTO system. In that case specific maneuvers would be required to treat AAA patients in an acute setting.
EXPERT OPINION: The ALTO system although being able to treat AAAs with adverse anatomy, it may not be appropriate during treatment of ruptured AAA patients with profound hemodynamic instability. A careful evaluation of the individual's patient anatomy and hemodynamic condition is mandatory in order to decide the best endograft for each case.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app