Determination of the P rp and Radial Dose Correction Factor in Reference Dosimetry.
Biomedical Physics & Engineering Express 2024 Februrary 3
OBJECTIVES: 
McEwen et al, (DOI: 10.1118/1.4866223) introduced a new factor Prp in addendum to TG-51 protocol to account for the radial dose distribution of the photon beam over the detector volume mainly in flattening filter free (FFF) beams. Prp and its extension to non-FFF beam reference dosimetry is investigated. Approches: The Prp was measured using simplified version of Sudhyadhom et al (DOI: 10.1118/1.4941691) for Elekta and Varian FFF beams with two detectors; PTW-30013 and Exradin-A12 ion chambers. For radial dose correction factor, the ion chambers were placed in a small water phantom and the central axis position was set to center of the sensitive volume on the treatment table and was studied by rotating the table by 15-degree interval from -90 to +90 degrees with respect to the initial (zero) position.
Main results:
The magnitude of Prp varies very little with machine, detector and beam energies to a value of 1.003 ± 0.0005 and 1.005 ± 0.0005 for 6FFF and 10FFF, respectively. The radial anisotropy for the Elekta machine with Exradin-A12 and PTW-30013 detector the magnitudes are in the range of (0.9995±0.0011 to 1.0015±0.0010) and (0.9998±0.0007 to 1.0015±0.0010), respectively. Similarly, for the Varian machine with Exradin-A12 and PTW-30013 ion chambers, the magnitudes are in the range of (1.0004±0.0010 to 1.0018±0.0018) and (1.0006±0.0009 to 1.0027±0.0007), respectively.
SIGNIFICANCE: The Prp is ≤ 0.3% and 0.5% for 6FFF and 10FFF, respectively. The radial dose correction factor in regular beams also does not impact the dosimetry where the maximum magnitude is ±0.2% which is within experimental uncertainty.
.
SIGNIFICANCE: The Prp is ≤ 0.3% and 0.5% for 6FFF and 10FFF, respectively. The radial dose correction factor in regular beams also does not impact the dosimetry where the maximum magnitude is ±0.2% which is within experimental uncertainty.
.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app