English Abstract
Journal Article
Add like
Add dislike
Add to saved papers

[The accuracy and feasibility study of freehand pedicle screw insertion for subaxial cervical spine asisited with safe core-referred technique].

Objective: To construct the "safe core" of the pedicle screw trajectory using CT imaging data of the subaxial cervical spine in adults, and to assess the accuracy and feasibility of the pedicle screw insertion asisited with the "safe core-referred" technique for subaxial cervical spine with a cadaver specimen study. Methods: This is an experimental study. From January 2015 to March 2020,60 adults' CT images data of the cervical spine were collected from the database of the First Affiliated Hospital of Gannan Medical Univercity,and were imported into Mimics 20.0 software. Virtual cervical pedicle trajectory and safe core were constructed according to the self-designed "virtual construction method of pedicle in the subaxial cervical spine". The success rate of the construction and the spatial position data of the virtual safe core of was recorded,including the distance between the safe core and the tangent line of the upper and lower outer edge of Luschka's joint on coronal plane,and the distance between the safe core and the posterior edge of the vertebral body on sagittal plane.The 3.5 mm column was used to simulate the pedicle screw placement,using the safe core as the only hub in pedicle screw trajectory.The length of the anterior pedicle screw trajectory,the interval of the abductive angle of the pedicle screw in axial plane, and the projection area of the entry area on periapical radiograph was calculated.In addition,8 adult cervical cadaver specimens were collected for the pedicle screw insertion experiment.The left side group used the "safe core-referred technique" for pedicle screw insertion,while the right side group used the Abumi method for pedicle screw insertion.The accuracy of pedicle screw placement was verified by CT scan.The difference between the accuracy of subjective judgment based on X-ray monitoring of operator and the actual accuracy of pedicle screw insertion verified by CT scan was compared between the two groups.The chi-square test was used to compare the intergroup data. Results: The total success rate of the virtual construction method for the safe core of the subaxial cervical spine was 97.0% (291/300); The distance between the safe core and the tangent line of the upper and lower outer edge of Luschka's joint on coronal plane was ( M (IQR)) 0.91 (0.98) mm (range: 0 to 1.85 mm);The distance between the safe core and the posterior wall on the sagittal plane of the vertebral body was (2.01±0.86) mm (range: 0.67 to 3.53 mm). The distance (anterior pedicle screw trajectory) from the posterior cortex to the central point of the safe core was (11.58±1.00)mm (range: 8.27 to 14.93 mm).The projection area of the entry point on the coronal plane was (36.18±11.67) mm2 (range: 13.38 to 83.11 mm2 ). Pedicle screw insertion experiment in cervical cadaver specimen showed the rate of intraoperative correction of the pedicle screw trajectory was 7.5% (3/40) in the experimental group and 12.5% (5/40) in the control group ( χ 2 =0.139, P =0.709). The operator 's correct rate of subjective judgment on CT in the stage of pedicle screw trajectory preparation was 100% (40/40) in the experimental group and 82.5% (33/40) in the control group, the difference was statistically significant ( χ 2 =5.638, P =0.018). The actual correct rate of CT verification in the stage of pedicle screw insertion was 100% (40/40) in the experimental group and 90.0% (36/40) in the control group, the difference was statistically significant ( χ 2 =2.368, P =0.124); The operator 's correct rate of subjective judgment in the stage of pedicle screw insertion completion was 100%(83/83) in the experimental group and 92.9% (79/85) in the control group ( χ 2 =4.199, P =0.040). Conclusions: The virtual safe-core of subaxial cervical spine can be use as a reliable anatomical fluoroscopy landmark for freehand pedicle screw insertion."Safe core-referred"technique can improve the accuracy rate of the operator's subjective judgment on the intraoperative fluoroscopy monitoring,and hence improve the accuracy of freehand pedicle screw insertion technology for subaxial cervical spine. And it still needs to be further verified in clinical practice.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app