We have located links that may give you full text access.
Sites of blood collection and topical disinfectants associated with contaminated cultures: An ambidirectional cohort study.
Journal of General and Family Medicine 2024 January
BACKGROUND: We aimed to determine whether puncture sites for blood sampling and topical disinfectants are associated with rates of contaminated blood cultures in the emergency department (ED) of a single institution.
METHODS: This single-center, ambidirectional cohort study of 548 consecutive patients ≥20 years of age was performed in the ED of a university hospital in Japan over a 13-month period. Pairs of blood samples were collected for aerobic and anaerobic cultures from patients in the ED. Physicians selected puncture sites and topical disinfectants according to their personal preference.
RESULTS: Potential contamination was identified in 110 of the 548 patients (20.1%). One hundred fourteen (20.8%) patients showed true-positive results for bacteremia, and 324 (59.1%) patients showed true-negative results. Multivariate analysis revealed more frequent contamination when puncture sites were disinfected with povidone-iodine (PVI) than with alcohol/chlorhexidine (ACHX) (adjusted risk difference, 19.1%; 95% confidence interval [CI]), 15.7-22.6; p < 0.001). In terms of blood collection sites, femoral and central venous (CV) catheter with PVI disinfection showed more frequent contamination than venous sites with ACHX (adjusted risk differences: 26.6%, 95% CI 21.3-31.9, p < 0.001 and 41.1%, 95% CI 22.2-59.9, p < 0.001, respectively).
CONCLUSION: Rates of contaminated blood cultures were significantly higher when blood was collected from the CV catheter or femoral sites with PVI as the topical disinfectant.
METHODS: This single-center, ambidirectional cohort study of 548 consecutive patients ≥20 years of age was performed in the ED of a university hospital in Japan over a 13-month period. Pairs of blood samples were collected for aerobic and anaerobic cultures from patients in the ED. Physicians selected puncture sites and topical disinfectants according to their personal preference.
RESULTS: Potential contamination was identified in 110 of the 548 patients (20.1%). One hundred fourteen (20.8%) patients showed true-positive results for bacteremia, and 324 (59.1%) patients showed true-negative results. Multivariate analysis revealed more frequent contamination when puncture sites were disinfected with povidone-iodine (PVI) than with alcohol/chlorhexidine (ACHX) (adjusted risk difference, 19.1%; 95% confidence interval [CI]), 15.7-22.6; p < 0.001). In terms of blood collection sites, femoral and central venous (CV) catheter with PVI disinfection showed more frequent contamination than venous sites with ACHX (adjusted risk differences: 26.6%, 95% CI 21.3-31.9, p < 0.001 and 41.1%, 95% CI 22.2-59.9, p < 0.001, respectively).
CONCLUSION: Rates of contaminated blood cultures were significantly higher when blood was collected from the CV catheter or femoral sites with PVI as the topical disinfectant.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app