Add like
Add dislike
Add to saved papers

Grading Clear Cell Renal Cell Carcinoma Grade Using Diffusion Relaxation Correlated MR Spectroscopic Imaging.

BACKGROUND: Clear cell renal cell carcinoma (ccRCC) is the most common subtype of RCC, and accurate grading is crucial for prognosis and treatment selection. Biopsy is the reference standard for grading, but MRI methods can improve and complement the grading procedure.

PURPOSE: Assess the performance of diffusion relaxation correlation spectroscopic imaging (DR-CSI) in grading ccRCC.

STUDY TYPE: Prospective.

SUBJECTS: 79 patients (age: 58.1 +/- 11.5 years; 55 male) with ccRCC confirmed by histopathology (grade 1, 7; grade 2, 45; grade 3, 18; grade 4, 9) following surgery.

FIELD STRENGTH/SEQUENCE: 3.0 T MRI scanner. DR-CSI with a diffusion-weighted echo-planar imaging sequence and T2-mapping with a multi-echo spin echo sequence.

ASSESSMENT: DR-CSI results were analyzed for the solid tumor regions of interest using spectrum segmentation with five sub-region volume fraction metrics (VA , VB , VC , VD , and VE ). The regulations for spectrum segmentation were determined based on the D-T2 spectra of distinct macro-components. Tumor size, voxel-wise T2, and apparent diffusion coefficient (ADC) values were obtained. Histopathology assessed tumor grade (G1-G4) for each case.

STATISTICAL TESTS: One-way ANOVA or Kruskal-Wallis test, Spearman's correlation (coefficient, rho), multivariable logistic regression analysis, receiver operating characteristic curve analysis, and DeLong's test. Significance criteria: P < 0.05.

RESULTS: Significant differences were found in ADC, T2, DR-CSI VB , and VD among the ccRCC grades. Correlations were found for ccRCC grade to tumor size (rho = 0.419), age (rho = 0.253), VB (rho = 0.553) and VD (rho = -0.378). AUC of VB was slightly larger than ADC in distinguishing low-grade (G1-G2) from high-grade (G3-G4) ccRCC (0.801 vs. 0.762, P = 0.406) and G1 from G2 to G4 (0.796 vs. 0.647, P = 0.175), although not significant. Combining VB , VD , and VE had better diagnostic performance than combining ADC and T2 for differentiating G1 from G2-G4 (AUC: 0.814 vs 0.643).

DATA CONCLUSION: DR-CSI parameters are correlated with ccRCC grades, and may help to differentiate ccRCC grades.

EVIDENCE LEVEL: 2 TECHNICAL EFFICACY STAGE: 2.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app