INTRODUCTION: Most patients undergoing a left atrial appendage occlusion (LAAO) procedure are admitted for overnight observation. A same-day discharge strategy offers the opportunity to improve resource utilization without compromising patient safety. We compared the patient safety outcomes and post-discharge complications between same-day discharge versus hospital admission (HA) (>1 day) in patients undergoing LAAO procedure.
METHODS: A systematic search of MEDLINE and Embase was conducted. Outcomes of interest included peri-procedural complications, re-admissions, discharge complications including major bleeding and vascular complications, ischemic stroke, all-cause mortality, and peri-device leak >5 mm. Mantel-Haenszel risk ratios (RRs) with 95% CIs were calculated.
RESULTS: A total of seven observational studies met the inclusion criteria. There was no statistically significant difference between same-day discharge versus HA regarding readmission (RR: 0.61; 95% confidence interval [CI]: [0.29-1.31]; p = .21), ischemic stroke after discharge (RR: 1.16; 95% CI: [0.49-2.73]), peri-device leak >5 mm (RR: 1.27; 95% CI: [0.42-3.85], and all-cause mortality (RR: 0.60; 95% CI: [0.36-1.02]). The same-day discharge study group had significantly lower major bleeding or vascular complications (RR: 0.71; 95% CI: [0.54-0.94]).
CONCLUSIONS: This meta-analysis of seven observational studies showed no significant difference in patient safety outcomes and post-discharge complications between same-day discharge versus HA. These findings provide a solid basis to perform a randomized control trial to eliminate any potential confounders.
METHODS: A systematic search of MEDLINE and Embase was conducted. Outcomes of interest included peri-procedural complications, re-admissions, discharge complications including major bleeding and vascular complications, ischemic stroke, all-cause mortality, and peri-device leak >5 mm. Mantel-Haenszel risk ratios (RRs) with 95% CIs were calculated.
RESULTS: A total of seven observational studies met the inclusion criteria. There was no statistically significant difference between same-day discharge versus HA regarding readmission (RR: 0.61; 95% confidence interval [CI]: [0.29-1.31]; p = .21), ischemic stroke after discharge (RR: 1.16; 95% CI: [0.49-2.73]), peri-device leak >5 mm (RR: 1.27; 95% CI: [0.42-3.85], and all-cause mortality (RR: 0.60; 95% CI: [0.36-1.02]). The same-day discharge study group had significantly lower major bleeding or vascular complications (RR: 0.71; 95% CI: [0.54-0.94]).
CONCLUSIONS: This meta-analysis of seven observational studies showed no significant difference in patient safety outcomes and post-discharge complications between same-day discharge versus HA. These findings provide a solid basis to perform a randomized control trial to eliminate any potential confounders.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app