Placing covered self-expanding metal stents by suspension laryngoscope in benign tracheal stenosis.

BACKGROUND: Tracheobronchial stent placement for malignant airway strictures has been proved to improve respiratory function, but experience for benign tracheobronchial stenoses is limited. The purpose of our study is to investigate the efficacy of covered expandable metallic stents, inserted through a suspension laryngoscope, treating tracheal stenosis following intubation or tracheostomy.

METHODS: From 2010 to 2018, 67 adult patients with the benign tracheal stenosis, underwent stent placement, using a suspension laryngoscope. According to the date of stent placement and stent caliber, these patients have been subdivided into two groups: Group 1 (from 2010 to 2013, stent caliber ranging from 16 to 20 mm) and Group 2 (from 2014 to 2018, stent caliber ranging from 18 to 22 mm). Complications, related reinterventions, and long-term prognosis were retrospectively evaluated.

RESULTS: Primary successful stent placement was achieved and symptoms were improved in all patients. Complications occurred in 27 (40.3%) cases. Among these, there were 14 (20.9%) cases with stent migration, 10 (14.93%) with granulation tissue formation and 3 (4.48%) with pneumonia. Stent migration in Group 1 was nearly 30% higher than that in Group 2 (P = 0.002). Five of the 8 patients who had placement of 16 mm stents had stent migration, more often than with 20 mm stents (P = 0.002). Ten patients' trachea had slight narrowing but without any symptoms. Six patients still had granulation tissue but without any growth at least two-year follow-up (2 patients whose stents were removed more than 1 year after placement). Even without tracheal narrowing and granulation tissue, 5 patients felt persistent shortness of breath. 92.5% of the patients reported to be satisfied with significant improvement in symptoms.

CONCLUSIONS: Patients with tracheal obstruction secondary to intubation or tracheostomy can benefit from tracheal stents. Placing 16 mm stents might lead to stent migration more easily than 20 mm stents. Tracheal stents placed by a suspension laryngoscope provide a reasonable alternative to open surgery for patients with benign tracheal stenosis or obstruction.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app