The Influence of Cervical Collar Immobilization on Optic Nerve Sheath Diameter.
Journal of Emergencies, Trauma, and Shock 2019 April
Background: Prior research has revealed that cervical collars elevate intracranial pressure (ICP) in patients with traumatic brain injury. Two recent small studies evaluated the change in optic sheath nerve diameter (ONSD) measured by ultrasound as a proxy for ICP following cervical collar placement in healthy volunteers.
Objective: We sought to validate the finding that ONSD measured by ultrasound increases after cervical collar placement within an independent data set.
Methods: This was a prospective, crossover study involving volunteers. Participants were randomized to either have the ONSD measured first without a cervical collar or initially with a cervical collar. Two sonographers performed independent ONSD diameter measurements. Continuous data were analyzed by matched-paired t -tests. Alpha was set at 0.05. The primary outcome parameter was the overall mean difference between ONSD measurements with the cervical collar on and off. Multiple linear regression was performed to examine the relationship between variables and the primary outcome parameter.
Results: There were 30 participants enrolled in the study. Overall mean ONSD for participants without the collar was 0.365 ± 0.071 cm and with the collar was 0.392 ± 0.081 cm. The mean change in ONSD for participants with and without the collar was 0.026 ± 0.064 cm (95% confidence interval of difference: 0.015-0.038; P < 0.001). Multiple regression analysis did not identify any variables associated with the variation in ONSD observed for collar versus noncollar.
Conclusions: We confirmed that ONSD does vary by a measurable amount with placement of a rigid cervical collar on healthy volunteers when assessed by ultrasound.
Objective: We sought to validate the finding that ONSD measured by ultrasound increases after cervical collar placement within an independent data set.
Methods: This was a prospective, crossover study involving volunteers. Participants were randomized to either have the ONSD measured first without a cervical collar or initially with a cervical collar. Two sonographers performed independent ONSD diameter measurements. Continuous data were analyzed by matched-paired t -tests. Alpha was set at 0.05. The primary outcome parameter was the overall mean difference between ONSD measurements with the cervical collar on and off. Multiple linear regression was performed to examine the relationship between variables and the primary outcome parameter.
Results: There were 30 participants enrolled in the study. Overall mean ONSD for participants without the collar was 0.365 ± 0.071 cm and with the collar was 0.392 ± 0.081 cm. The mean change in ONSD for participants with and without the collar was 0.026 ± 0.064 cm (95% confidence interval of difference: 0.015-0.038; P < 0.001). Multiple regression analysis did not identify any variables associated with the variation in ONSD observed for collar versus noncollar.
Conclusions: We confirmed that ONSD does vary by a measurable amount with placement of a rigid cervical collar on healthy volunteers when assessed by ultrasound.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app