Comparison of defect depths for sinusoidal and circular perimetric stimuli in patients with glaucoma.

PURPOSE: Clinical use of perimetric testing in patients with glaucoma typically assumes that perimetric defects will be less deep for larger than smaller stimuli. However, studies have shown that very large sinusoidal stimuli can yield similar defects as small circular stimuli. In order to provide guidelines for new perimetric stimuli, we tested patients with glaucoma using five different stimuli and compared defects to their patterns of retinal nerve fibre layer (RNFL) damage.

METHODS: Twenty subjects with glaucoma were imaged with optical coherence tomography (OCT) volume scans to allow for en face RNFL images and were also tested on a custom perimetry station with five stimuli: Goldmann sizes III and V, a two-dimensional Gaussian blob (standard deviation 0.5°) and a 0.5 cycle degree-1 sinusoidal grating presented two ways: flickered at 5 Hz, and pulsed for 200 ms instead of flickered. En face RNFL images were reviewed with the visual field locations overlaid, and each location was labelled for a patient as either no visible RNFL defect or as wedge, slit, edge, or diffuse defect. Nineteen age-similar controls were tested with the same stimuli to define depth of defect as difference from mean normal. Bland-Altman analysis was used to test three predictions of neural modelling by making five comparisons.

RESULTS: Bland-Altman analysis confirmed the three predictions. The flickered sinusoid gave deeper defects in damaged areas than the pulsed sinusoid (r = 0.25, p < 0.0001). When comparing data for sizes III and V there was increased spread of the data in deeper defects in the direction of size III having deeper defect (r = 0.35, p < 0.0001). The size V stimulus yielded shallower defects than a stimulus of similar size but with blurred edges (r = 0.20, p = 0.0004).

CONCLUSIONS: On average, all stimuli produced similar results comparing across type of RNFL damage. However, there were systematic patterns consistent with predictions of neural modelling: in damaged areas, depth of defect tended to be greater for the flickered sinusoid than the pulsed sinusoid, greater for the size III stimulus than the size V stimulus, and greater for the Gaussian blob than for the size V stimulus.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app