Mitroflow LXA structural deterioration following aortic valve replacement: a single-center experience.
Journal of Cardiovascular Surgery 2018 October
BACKGROUND: Concerns have been previously raised regarding the potential early degeneration of the Mitroflow (Sorin Group Italia, Saluggia, Vercelli, Italy) bioprostheses. We aimed to evaluate our clinical experience with the Mitroflow LXA prosthesis for aortic valve replacement.
METHODS: We prospectively analyzed data from 227 consecutive patients (133 males, mean age 73.9±9.2 years) implanted with the Mitroflow LXA between February 2007 and October 2011. Follow-up data were obtained by contacting the referring cardiologists. Kaplan-Meier curves were constructed for all-cause mortality, valve related mortality and structural valve degeneration (SVD). Multivariable analysis was conducted to identify SVD predictors.
RESULTS: Median follow-up time was 54.2±37.9 months and completeness of follow-up was 95%. Overall mortality in the entire series was at 31% (N.=71) and mortality from cardiac or unknown causes at 20% (N.=46). SVD occurred in 24 patients (10%) (median delay between implantation and diagnosis: 62.6 (36.5) months). Reintervention was required in 20 cases (13 redo surgery, 7 percutaneous transcatheter valve intervention). The 8 years actuarial global survival was 54.7±4.9%, freedom from valve related mortality 67.5±4.9% and freedom from SVD 72±8%. The estimated freedom from SVD was significantly (P=0.007) longer in larger prosthesis (diameter >21 mm, 77±11%) compared to the smaller devices (≤21 mm, 59±13%.). Multivariate analysis identified smaller prostheses and age at implantation as independent predictors of SVD.
CONCLUSIONS: The Mitroflow LXA showed evidence of early SVD in this cohort. A close follow-up of these patients is strongly advised.
METHODS: We prospectively analyzed data from 227 consecutive patients (133 males, mean age 73.9±9.2 years) implanted with the Mitroflow LXA between February 2007 and October 2011. Follow-up data were obtained by contacting the referring cardiologists. Kaplan-Meier curves were constructed for all-cause mortality, valve related mortality and structural valve degeneration (SVD). Multivariable analysis was conducted to identify SVD predictors.
RESULTS: Median follow-up time was 54.2±37.9 months and completeness of follow-up was 95%. Overall mortality in the entire series was at 31% (N.=71) and mortality from cardiac or unknown causes at 20% (N.=46). SVD occurred in 24 patients (10%) (median delay between implantation and diagnosis: 62.6 (36.5) months). Reintervention was required in 20 cases (13 redo surgery, 7 percutaneous transcatheter valve intervention). The 8 years actuarial global survival was 54.7±4.9%, freedom from valve related mortality 67.5±4.9% and freedom from SVD 72±8%. The estimated freedom from SVD was significantly (P=0.007) longer in larger prosthesis (diameter >21 mm, 77±11%) compared to the smaller devices (≤21 mm, 59±13%.). Multivariate analysis identified smaller prostheses and age at implantation as independent predictors of SVD.
CONCLUSIONS: The Mitroflow LXA showed evidence of early SVD in this cohort. A close follow-up of these patients is strongly advised.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app