We have located links that may give you full text access.
One-Per-Mil Tumescent Infiltration Technique for Vascular Malformation Surgery in Hand and Upper Extremity.
Hand Surgery 2015 October
BACKGROUND: To present the efficacy of 1:1,000,000 tumescent solution for resection of vascular malformation in hand and upper extremity without tourniquet application.
METHODS: Four patients with five slow flow vascular malformations were retrospectively reviewed. Prior to incision, 1:1,000,000 tumescent solution was infiltrated subcutaneously surrounding the lesion until the skin turned pale. Amount of tumescent solution injected, the length of surgery, the clarity of the operative field, and the complications were recorded. Clarity of operative field was categorized as totally bloodless, minimum bleeding, acceptable bleeding, and bloody. In the surgeries under local anesthesia, we also recorded self-reported intra-operative pain using VAS score, onset of pain, and conversion of anesthesia.
RESULTS: The injected amount of the tumescent solution ranged from 4.5 to 200 mL, with the length of surgery ranged from 60 to 150 minutes. One out of 5 cases was totally bloodless, 3 cases were minimum bleeding and 1 case was acceptable bleeding. Minor skin necrosis was recorded in 1 patient. Neither intra-operative pain nor conversion from local to general anesthesia was reported.
CONCLUSIONS: 1:1,000,000 tumescent solution is effective for resection of slow flow vascular malformation in hand and upper extremity without tourniquet application.
METHODS: Four patients with five slow flow vascular malformations were retrospectively reviewed. Prior to incision, 1:1,000,000 tumescent solution was infiltrated subcutaneously surrounding the lesion until the skin turned pale. Amount of tumescent solution injected, the length of surgery, the clarity of the operative field, and the complications were recorded. Clarity of operative field was categorized as totally bloodless, minimum bleeding, acceptable bleeding, and bloody. In the surgeries under local anesthesia, we also recorded self-reported intra-operative pain using VAS score, onset of pain, and conversion of anesthesia.
RESULTS: The injected amount of the tumescent solution ranged from 4.5 to 200 mL, with the length of surgery ranged from 60 to 150 minutes. One out of 5 cases was totally bloodless, 3 cases were minimum bleeding and 1 case was acceptable bleeding. Minor skin necrosis was recorded in 1 patient. Neither intra-operative pain nor conversion from local to general anesthesia was reported.
CONCLUSIONS: 1:1,000,000 tumescent solution is effective for resection of slow flow vascular malformation in hand and upper extremity without tourniquet application.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app