Real-time ultrasound-guided placement of a pigtail catheter in supine position for draining pleural effusion in pediatric patients who have undergone liver transplantation.

PURPOSE: Ultrasound (US) guidance is currently used for placement of wire-guided thoracic drains, and its use is associated with a decreased risk of complications. However, most studies conducted to date in this field have been performed on adult patients. The aim of this study was to report the technical success and complication rates observed during real-time US-guided placement of a thoracic pigtail catheter in pediatric liver-transplant recipients with symptomatic pleural effusion.

METHODS: This was a single-center retrospective review of the clinical records and images from pediatric liver-transplant patients with symptomatic pleural effusion who had undergone real-time US-guided pleural-space puncture followed by placement (via the Seldinger technique) of a pigtail catheter for drainage, between May 2006 and June 2014.

RESULTS: We identified 25 patients who had undergone 41 pigtail catheter-placement procedures during the study period. The patients' mean age (± SD) was 4.2 ± 3.9 years (range, 2 months to 16 years), and their mean weight was 14.2 ± 7.2 kg (range, 4.5-33 kg). Seventeen procedures had been performed in the intensive care unit, and 8, in patients undergoing mechanical ventilation. Twelve of the 41 procedures had been performed in patients with altered hemostasis (ie, platelet count < 50 × 10(3) /μl and/or international normalized ratio > 1.5). The size of the pigtail catheters ranged from 5 F to 8.5 F. The technical success rate was 100%, with no major complications such as pneumothorax or hemothorax. Accidental dislocation of the catheter occurred in four patients (9%) over 3-10 days after the first procedure.

CONCLUSIONS: In our experience, real-time US-guided pleural-space puncture, performed at bedside, with the patient in the supine position, followed by placement of a pigtail catheter for drainage of effusion, is safe to use and has a high rate of technical success in pediatric patients. © 2015 Wiley Periodicals, Inc. J Clin Ultrasound 44:284-289, 2016.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app