An updated systematic review and meta-analysis on impedance threshold devices in patients undergoing cardiopulmonary resuscitation.

INTRODUCTION: Uncertainty persists on the clinical impact of impedance threshold devices in out-of-hospital cardiac arrest. We conducted an updated systematic review on impedance threshold devices.

METHODS: Several databases were searched for studies testing the effectiveness of impedance threshold devices in patients with cardiac arrest. The primary endpoint was long-term survival.

RESULTS: Seven trials (11,254 patients) were included. In 4 studies (2,284 patients) impedance threshold devices were used with active compression-decompression-cardiopulmonary resuscitation, and in the others alone. Overall, impedance threshold devices did not impact on the rate of return of spontaneous circulation (odds ratio=1.17 [0.96-1.43], p=0.114), favorable neurologic outcome (odds ratio=1.56 [0.97-2.50], p=0.065), or long-term survival (odds ratio=1.22 [0.94-1.58], p=0.127). These analyses were fraught with heterogeneity (respectively, p=0.055, p=0.236, and p=0.011) and inconsistency (respectively, I-squared=51% , I-squared=27% , and I-squared=67%). Exploratory analysis showed that combined use of impedance threshold devices with active compression-decompression significantly increased the likelihood of return of spontaneous circulation (odds ratio=1.19 [1.00-1.40], p=0.045), favorable neurologic outcome (odds ratio=1.60 [1.14-2.25], p=0.006), and long-term survival (odds ratio=1.52 [1.11-2.08], p=0.009). The favorable impact of the interaction between impedance threshold devices and active compression-decompression was also confirmed at meta-regression analysis (respectively, b=0.195 [0.004-0.387], p=0.045, b=0.500 [0.079-0.841], p=0.018, b=0.413 [0.063-0.764], p=0.021).

CONCLUSIONS: The evidence base on impedance threshold devices is apparently inconclusive, with a neutral impact on clinically relevant outcomes. However, exploratory analysis focusing on the combined use of impedance threshold devices with active compression-decompression suggests that this combo treatment may be useful to improve patient prognosis.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app