Clinical Trial
Comparative Study
Journal Article
Research Support, Non-U.S. Gov't
Add like
Add dislike
Add to saved papers

Comparison of three high flow oxygen therapy delivery devices: a clinical physiological cross-over study.

AIM: High-flow-oxygen-therapy is provided by various techniques and patient interfaces, resulting in various inspired-fraction of oxygen (FiO2) and airway-pressure levels. However, tracheal measurements have never been performed.

METHODS: Three oxygen-delivery-devices were evaluated: 1) standard-high-flow-oxygen-facemask with reservoir-bag, 2) Optiflow(TM)-high-flow-nasal-cannulae and 3) Boussignac(TM)-oxygen-therapy-system. Main judgment criteria were airway-pressure and FiO2 measured in the trachea. The three devices were randomly evaluated in cross-over in 10 Intensive-Care-Unit patients using three oxygen flow-rates (15, 30 and 45 L/min) and two airway-tightness conditions (open and closed mouth). Airway-pressures and FiO2 were measured by a tracheal-catheter inserted through the hole of a tracheotomy tube. Comfort was evaluated by self-reporting. Data are presented as median [25-75th].

RESULTS: 1) Regarding oxygen-delivery devices, BoussignacTM provided the highest mean tracheal pressure (13.9 [10.4-14.5] cmH20) compared to Optiflow(TM) (2 [1-2.3] cmH2O, P<0.001). BoussignacTM provided both positive inspiratory and expiratory airway-pressures, whereas Optiflow(TM) provided only positive expiratory airway-pressure. Reservoir-bag-facemask provided airway pressure close to zero. For FiO2, highest value was obtained for both Optiflow(TM) and facemask (90%) compared to Boussignac(TM) (80%), P<0.01. 2) Regarding oxygen-flow, airway-pressure and FiO2 systematically increased with oxygen-flow with the three devices except airway-pressure for the facemask. 3) Regarding the open-mouth position, mean airway-pressure decreased with Optiflow(TM) only (2 [1.2-3.3] vs. 0.6 [0.3-1] cmH2O, P<0.001). Opening the mouth had little impact on FiO2. 4) finally, discomfort-intensities were low for both Optiflow(TM) and reservoir-bag-facemask compared to Boussignac(TM), P<0.01.

CONCLUSION: On one hand, Boussignac(TM) is the only device that generates a relevant positive-airway-pressure during both inspiration-and-expiration, independently of mouth-position. Optiflow(TM) provides a low positive-airway-pressure (<4 cmH2O), highly dependent of mouth-closing. The reservoir-bag-facemask provides no positive-airway-pressure. On the other hand, FiO2 are slightly but significantly higher for Optiflow(TM) and reservoir-bag-facemask than for Boussignac(TM). Discomfort was lesser for Optiflow(TM) and reservoir-bag-facemask.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app