Nine-month results of the REFORM study: a prospective, single-arm, multicenter clinical study of the safety and effectiveness of the Formula™ balloon-expandable stent for treatment of renal artery stenosis

Robert M Bersin, Gary Ansel, Anthony Rizzo, H Bob Smouse, Shantanu Sinha, Ravish Sachar, Rajesh Dave, Barry S Weinstock, Robert Feldman, Gary S Roubin
Catheterization and Cardiovascular Interventions 2013 August 1, 82 (2): 266-73
22581488

OBJECTIVES: To evaluate the 9-month safety and effectiveness outcomes of the Formula™ balloon-expandable renal stent (Cook Medical, Bloomington, IN) for the treatment of atherosclerotic renal artery stenosis (RAS) following suboptimal angioplasty.

BACKGROUND: Atherosclerotic RAS can cause hypertension and ischemic nephropathy. When clinically indicated, an interventional approach with renal angioplasty and stent implantation is the preferred method for revascularization of atherosclerotic renal artery stenoses.

METHODS: The REFORM study is a prospective, multicenter, single-arm study of stent implantation following suboptimal PTRA using the Formula stent. One hundred patients with atherosclerotic ostial renal artery lesions =18 mm in length with a >50% residual stenosis following PTA were enrolled. The primary endpoint was 9-month primary patency.

RESULTS: The 9-month primary patency rate was 91.7%. The 9-month major adverse event rate was 2.2%. Mean systolic blood pressure was significantly decreased at follow-up (from 150 ± 21 mm Hg at baseline to 141 ± 21 mm Hg at 9 months; P = 0.003). Mean serum creatinine (SCr) level and mean estimated glomerular filtration rate (eGFR) were not significantly different at 9 months. A clinically meaningful improvement in renal function (i.e., =25% increase in eGFR or =0.5 mg/dl decrease in SCr) was observed in 9% of patients at 1 month and 12% of patients at 9 months. A clinically meaningful decline in renal function (i.e., =25% decrease in eGFR or =0.5 mg/dl increase in SCr) was observed in only 3% of patients at 1 month and 7% of patients at 9 months.

CONCLUSIONS: The Formula stent was safe and effective in treating atherosclerotic RAS following suboptimal angioplasty.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
22581488
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"