We have located links that may give you full text access.
Crestal bone loss evaluation in osseotite expanded platform implants: a 5-year study.
Clinical Oral Implants Research 2011 December
OBJECTIVE: The aim of this prospective clinical study was to evaluate the survival rates at 5 years of expanded platform implants placed in the anterior zone of the maxilla and immediately restored with single crowns.
MATERIALS AND METHODS: Implants incorporating the platform-switching concept were placed in fresh extraction sockets in the maxillary arch, with each patient receiving a provisional restoration immediately after implant placement. After 15 days, final screwed restorations were inserted. Mesial and distal bone heights were evaluated using digital radiography on the day following implant placement and at 1, 3, 6, 9, 12, 24, 36 months and 5 years. Primary stability was measured with resonance frequency analysis (RFA) using the Osstell Mentor device. Sixty-four implants were placed in 32 men and 32 women ranging in age between 29 and 60 (mean: 39.64 ± 5.16 years).
RESULTS: Mean mesial bone loss was 0.08 mm (SD 0.42). Mean distal bone loss was 0.14 mm (SD 0.56). Over the course of the 5 years, the mean RFA value was 72.5 ± 3.1 SD.
CONCLUSION: The platform-switched implants remained stable over the course of 5 years and had an overall survival rate of 97.1%.
MATERIALS AND METHODS: Implants incorporating the platform-switching concept were placed in fresh extraction sockets in the maxillary arch, with each patient receiving a provisional restoration immediately after implant placement. After 15 days, final screwed restorations were inserted. Mesial and distal bone heights were evaluated using digital radiography on the day following implant placement and at 1, 3, 6, 9, 12, 24, 36 months and 5 years. Primary stability was measured with resonance frequency analysis (RFA) using the Osstell Mentor device. Sixty-four implants were placed in 32 men and 32 women ranging in age between 29 and 60 (mean: 39.64 ± 5.16 years).
RESULTS: Mean mesial bone loss was 0.08 mm (SD 0.42). Mean distal bone loss was 0.14 mm (SD 0.56). Over the course of the 5 years, the mean RFA value was 72.5 ± 3.1 SD.
CONCLUSION: The platform-switched implants remained stable over the course of 5 years and had an overall survival rate of 97.1%.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app