Reduction in surface contamination with antineoplastic drugs in 22 hospital pharmacies in the US following implementation of a closed-system drug transfer device.
Journal of Oncology Pharmacy Practice 2011 March
PURPOSE: Surface contamination with the antineoplastic drugs cyclophosphamide, ifosfamide, and 5-fluorouracil was compared in 22 US hospital pharmacies following preparation with standard drug preparation techniques or the PhaSeal® closed-system drug transfer device (CSTD).
METHODS: Wipe samples were taken from biological safety cabinet (BSC) surfaces, BSC airfoils, floors in front of BSCs, and counters and analyzed for contamination with cyclophosphamide, ifosfamide, and 5-fluorouracil. Contamination was reassessed several months after the implementation of the CSTD. Surface contamination (ng/cm(2)) was compared between the two techniques and evaluated with the Signed Rank Test.
RESULTS: Using the CSTD compared to the standard preparation techniques, a significant reduction in levels of contamination was observed for all drugs (cyclophosphamide: p < 0.0001; ifosfamide: p < 0.001; 5-fluorouracil: p < 0.01). Median values for surface contamination with cyclophosphamide, ifosfamide, and 5-fluorouracil were reduced by 95%, 90%, and 65%, respectively.
CONCLUSIONS: Use of the CSTD significantly reduces surface contamination when preparing cyclophosphamide, ifosfamide, and 5-fluorouracil as compared to standard drug preparation techniques.
METHODS: Wipe samples were taken from biological safety cabinet (BSC) surfaces, BSC airfoils, floors in front of BSCs, and counters and analyzed for contamination with cyclophosphamide, ifosfamide, and 5-fluorouracil. Contamination was reassessed several months after the implementation of the CSTD. Surface contamination (ng/cm(2)) was compared between the two techniques and evaluated with the Signed Rank Test.
RESULTS: Using the CSTD compared to the standard preparation techniques, a significant reduction in levels of contamination was observed for all drugs (cyclophosphamide: p < 0.0001; ifosfamide: p < 0.001; 5-fluorouracil: p < 0.01). Median values for surface contamination with cyclophosphamide, ifosfamide, and 5-fluorouracil were reduced by 95%, 90%, and 65%, respectively.
CONCLUSIONS: Use of the CSTD significantly reduces surface contamination when preparing cyclophosphamide, ifosfamide, and 5-fluorouracil as compared to standard drug preparation techniques.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app