Diffusion tensor magnetic resonance imaging of the normal breast.
Magnetic Resonance Imaging 2010 April
PURPOSE: The objective of this study was to evaluate diffusion anisotropy of the breast parenchyma and assess the range and repeatability of diffusion tensor imaging (DTI) parameters in normal breast tissue.
MATERIALS AND METHODS: The study was approved by our institutional review board and included 12 healthy females (median age, 36 years). Diffusion tensor imaging was performed at 1.5 T using a diffusion-weighted echo planar imaging sequence. Diffusion tensor imaging parameters including tensor eigenvalues (lambda(1), lambda(2), lambda(3)), fractional anisotropy (FA) and apparent diffusion coefficient (ADC) were measured for anterior, central and posterior breast regions.
RESULTS: Mean normal breast DTI measures were lambda(1)=2.51 x 10(-3) mm(2)/s, lambda(2)=1.89 x 10(-3) mm(2)/s, lambda(3)=1.39 x 10(-3) mm(2)/s, ADC=1.95+/-0.24 x 10(-3) mm(2)/s and FA=0.29+/-0.05 for b=600 s/mm(2). Significant regional differences were observed for both FA and ADC (P<.05), with higher ADC in the central breast and higher FA in the posterior breast. Comparison of DTI values calculated using b=0, 600 s/mm(2) vs. b=0, 1000 s/mm(2), showed significant differences in ADC (P<.001), but not FA. Repeatability assessment produced within-subject coefficient of variations of 4.5% for ADC and 11.4% for FA measures.
CONCLUSION: This study demonstrates anisotropy of water diffusion in normal breast tissue and establishes a normative range of breast FA values. Attention to the influence of breast region and b value on breast DTI measurements may be important for clinical interpretation and standardization of techniques.
MATERIALS AND METHODS: The study was approved by our institutional review board and included 12 healthy females (median age, 36 years). Diffusion tensor imaging was performed at 1.5 T using a diffusion-weighted echo planar imaging sequence. Diffusion tensor imaging parameters including tensor eigenvalues (lambda(1), lambda(2), lambda(3)), fractional anisotropy (FA) and apparent diffusion coefficient (ADC) were measured for anterior, central and posterior breast regions.
RESULTS: Mean normal breast DTI measures were lambda(1)=2.51 x 10(-3) mm(2)/s, lambda(2)=1.89 x 10(-3) mm(2)/s, lambda(3)=1.39 x 10(-3) mm(2)/s, ADC=1.95+/-0.24 x 10(-3) mm(2)/s and FA=0.29+/-0.05 for b=600 s/mm(2). Significant regional differences were observed for both FA and ADC (P<.05), with higher ADC in the central breast and higher FA in the posterior breast. Comparison of DTI values calculated using b=0, 600 s/mm(2) vs. b=0, 1000 s/mm(2), showed significant differences in ADC (P<.001), but not FA. Repeatability assessment produced within-subject coefficient of variations of 4.5% for ADC and 11.4% for FA measures.
CONCLUSION: This study demonstrates anisotropy of water diffusion in normal breast tissue and establishes a normative range of breast FA values. Attention to the influence of breast region and b value on breast DTI measurements may be important for clinical interpretation and standardization of techniques.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app