Add like
Add dislike
Add to saved papers

Reliability and diagnostic accuracy of 5 physical examination tests and combination of tests for subacromial impingement.

OBJECTIVE: To investigate the reliability and diagnostic accuracy of individual tests and combination of tests for subacromial impingement syndrome (SAIS).

DESIGN: A prospective, blinded study design.

SETTING: Orthopedic surgeon shoulder clinic.

PARTICIPANTS: Patients with shoulder pain (n=55, mean age=40.6y).

INTERVENTIONS: Patients were evaluated with 5 physical examination tests for SAIS: Neer, Hawkins-Kennedy, painful arc, empty can (Jobe), and external rotation resistance tests. Surgical diagnosis was the reference standard.

MAIN OUTCOME MEASURES: Diagnostic accuracy calculated with a receiver operating characteristic (ROC) curve and sensitivity, specificity, positive likelihood ratio (+LR), and negative likelihood ratio (-LR). A forward stepwise binary logistic regression analysis was used to determine the best test combination for SAIS. An ROC curve analysis was also used to determine the cut point of the number of tests discriminating between the presence and absence of SAIS. Kappa coefficients and percent agreement assessed interrater reliability.

RESULTS: The ROC analyses revealed a significant area under the curve (AUC) (AUC=.67-.72, P<.05) for all tests, except for the Hawkins-Kennedy. The tests with a +LR greater than or equal to 2.0 were the painful arc (+LR=2.25; 95% CI, 1.33-3.81), empty can (+LR=3.90; 95% CI, 1.5-10.12), and the external rotation resistance tests (+LR=4.39; 95% CI, 1.74-11.07). Tests with -LR less than or equal to 0.50 were the painful arc (-LR=.38; 95% CI, .16-.90), external rotation resistance (-LR=.50; 95% CI, .28-.89), and Neer tests (-LR=.35; 95% CI, .12-.97). The regression analysis had no specific test combinations for confirming or ruling out SAIS. The ROC analysis was significant (AUC=.79, P=.001), with a cut point of 3 positive tests out of 5 tests. Reliability was moderate to substantial agreement (kappa=.45-.67) for the painful arc, empty can, and external rotation resistance tests and fair strength of agreement (kappa=.39-.40) for the Neer and Hawkins-Kennedy tests.

CONCLUSIONS: The single tests of painful arc, external rotation resistance, and Neer are useful screening tests to rule out SAIS. The single tests of painful arc, external rotation resistance, and empty can are helpful to confirm SAIS. The reliability of all tests was acceptable for clinical use. Based on reliability and diagnostic accuracy, the single tests of the painful arc, external rotation resistance, and empty can have the best overall clinical utility. The cut point of 3 or more positive of 5 tests can confirm the diagnosis of SAIS, while less than 3 positive of 5 rules out SAIS.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app