In Vitro
Journal Article
Add like
Add dislike
Add to saved papers

Microleakage of class V cavities with different adhesive systems prepared by a diamond instrument and different parameters of Er:YAG laser irradiation.

OBJECTIVE: The aim of this study was to evaluate the microleakage of composite resin restorations using two different dentine adhesive systems prepared with a diamond instrument and different parameters of Er:YAG laser irradiation.

BACKGROUND DATA: Information on this topic with regard to preparing class V cavities with different parameters of Er:YAG laser irradiation and adhesive systems is scarce.

MATERIALS AND METHODS: Two hundred class V cavities were assigned to ten groups (n = 20 each): group 1: Er:YAG laser (5 Hz, 600 mJ) + phosphoric acid (PA) + Adper Single Bond 2 (ASB2); group 2: Er:YAG laser (10 Hz, 300 mJ) + PA + ASB2; group 3: Er:YAG laser (15 Hz, 200 mJ) + PA + ASB2; group 4: Er:YAG laser (20 Hz, 150 mJ) + PA + ASB2; group 5: diamond instrument + PA + ASB2; group 6: Er:YAG laser (5 Hz, 600 mJ) + Adper Prompt L-Pop (APLP); group 7: Er:YAG laser (10 Hz, 300 mJ) + APLP; group 8: Er:YAG laser (15 Hz, 200 mJ) + APLP; group 9: Er:YAG laser (20 Hz, 150 mJ) + APLP; and group 10: diamond instrument + APLP. Cavities were restored with a nanofill composite (Filtek Supreme XT Body). After thermocycling, the specimens were stained with 0.5% aqueous basic fuchsin dye and sectioned bucco-lingually. Dye penetration was then scored. The data were analyzed using the Kruskal-Wallis and Mann-Whitney U tests with Bonferroni correction. The Wilcoxon signed ranks test was used to compare occlusal and gingival scores.

RESULTS: Leakage was seen in all groups at both the occlusal and gingival margins. The Kruskal-Wallis test showed statistically significant differences among the 10 groups (p < 0.001). The gingival margins had more microleakage than the occlusal margins (p < 0.001). Pairwise analysis by the Mann-Whitney U test showed that statistically significant differences (p < 0.05) in microleakage were found between groups 3 and 5 (3 > 5), 5 and 7 (7 > 5), and 7 and 8 (7 > 8) at the gingival margin, and between groups 3 and 6 (6 > 3), 3 and 7 (7 > 3), 4 and 6 (6 > 4), and 4 and 7 (7 > 4) at the occlusal margin.

CONCLUSION: We concluded that for all groups, microleakage values were higher at the gingival margins. The use of the Er:YAG laser for cavity preparation with different parameters and different dentine adhesive systems influenced the marginal sealing of composite resin restorations.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app