Low-profile stent system for treatment of atherosclerotic renal artery stenosis: the GREAT trial.

PURPOSE: The Palmaz Genesis Peripheral Stainless Steel Balloon Expandable Stent in Renal Artery Treatment (GREAT) Trial was designed to assess the safety and performance of a low-profile stent for the treatment of obstructive renal artery disease by looking at 6-month renal artery patency uniformly analyzed by a Core Lab.

MATERIALS AND METHODS: Fifty-two consecutive patients (mean age, 63.7 years) were successfully treated with the Palmaz Genesis Peripheral Stent (Cordis, Miami, FL) on the Slalom 0.018-inch Delivery System (Cordis Europe N.V., Oosteinde 8, NLO-9301 LJ Roden, The Netherlands) at 11 investigational centers. Patients with severe renal failure and > 8-mm renal artery were excluded. Primary endpoint was angiographic determination of in-stent percent diameter stenosis at 6 months. Fifty-one patients were treated with one stent, one patient was treated with two stents to cover the complete lesion.

RESULTS: Mean percentage diameter stenosis before renal angioplasty was 68.2% +/- 12.0%. No stent implantation failure, displacement, need for additional stent implantation, or procedural complication was observed. Six-month angiography was performed in 41 of 52 patients (79%) resulting in a mean in-stent percent diameter stenosis or Quantitative Vessel analysis (QVA) at 6 months of 23.9%. The in-stent binary (percent diameter stenosis > 50%) restenosis rate at 6 months was 14.3%. No fatal events occurred up to 6 months after implantation. Major adverse events occurred in five patients: four patients (7.7%) required a revascularization and one patient (1.9%) experienced a cerebrovascular event, which regressed spontaneously.

CONCLUSIONS: The Palmaz Genesis stent (Cordis) provides good results for renal artery stent placement, with an in-stent binary restenosis rate (percent diameter stenosis > 50%) at 6 months of 14.3% as determined with angiography.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app