Residual stenosis after conventional balloon angioplasty for hemodialysis shunt failure: treatment with metallic stent placement and post-balloon dilatation.
Radiation Medicine 2005 Februrary
PURPOSE: The usefulness of metallic stent placement and post-balloon dilatation was investigated for patients with residual stenosis after conventional percutaneous transluminal balloon angioplasty (balloon PTA) of dialysis shunt vessels.
MATERIALS AND METHODS: Among 92 patients who had received balloon PTA for dialysis shunt vessels, seven patients who showed a residual waist on the balloon even under maximum inflation were enrolled in this study. In these patients with residual stenosis after balloon PTA, we inserted a stent in the residual stenosis, and post-balloon dilatation was immediately applied using the same balloon catheter.
RESULTS: After balloon PTA, the average percent diameter stenosis declined to 45.5 +/- 7.30%, and the stenosis was further improved to an average of 19.3 +/- 7.09% after the placement of a stent and the additional balloon PTA. The average percent diameter dilatation of the balloon before the placement of a stent was 65.8 +/- 12.7%, while the average dilatation increased to 84.1 +/- 8.96% after the placement of a stent. Dialysis became possible immediately after the procedure in all cases.
CONCLUSION: Metallic stent placement and post-balloon dilatation was effective for patients with residual stenosis after conventional balloon PTA of dialysis shunt vessels.
MATERIALS AND METHODS: Among 92 patients who had received balloon PTA for dialysis shunt vessels, seven patients who showed a residual waist on the balloon even under maximum inflation were enrolled in this study. In these patients with residual stenosis after balloon PTA, we inserted a stent in the residual stenosis, and post-balloon dilatation was immediately applied using the same balloon catheter.
RESULTS: After balloon PTA, the average percent diameter stenosis declined to 45.5 +/- 7.30%, and the stenosis was further improved to an average of 19.3 +/- 7.09% after the placement of a stent and the additional balloon PTA. The average percent diameter dilatation of the balloon before the placement of a stent was 65.8 +/- 12.7%, while the average dilatation increased to 84.1 +/- 8.96% after the placement of a stent. Dialysis became possible immediately after the procedure in all cases.
CONCLUSION: Metallic stent placement and post-balloon dilatation was effective for patients with residual stenosis after conventional balloon PTA of dialysis shunt vessels.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app