[Splenic and bone marrow increased 18F-FDG uptake in a PET scan performed following treatment with G-CSF].
Revista Española de Medicina Nuclear 2004 March
We present the case of an 11 year-old Caucasian girl who presented chest pain of 12 weeks evolution, with no other symptoms and a negative physical examination. Lactate dehydrogenase levels were increased to 797 U/l, whereas beta-2-microglobulin (BM2) levels were normal. The thoracic CT showed a bulky mediastinal mass that occupied the pretracheal, paratracheal and right prevascular regions. The gallium scintigraphy showed high uptake in the mediastinic region; the bone scintigraphy was negative. Biopsy of the mediastinal mass revealed the presence of diffuse large B-cell non-Hodgkin's lymphoma. Treatment included 4 cycles of chemotherapy followed by 7 days of subcutaneous granulocyte colony-stimulating factor (G-CSF, Lenogastrim) at a dose of 5 mg/Kg/day. Following treatment, a CT scan was performed to evaluate response, finding a calcification of the mass without significant reduction of the overall size. Because CT was inconclusive in the assessment of response to therapy, a 18F-FDG PET scan was performed. The 18F-FDG PET scan did not show any pathological uptake in the mediastinum but revealed a splenic and bone marrow diffusely increased 18F-FDG uptake. The differential diagnosis included a secondary effect induced by G-CSF therapy as one of the main possibilities, but other possibilities such as a malignant infiltration by lymphoma could not be discarded. Therefore, a second 18F-FDG PET scan was performed 3 months later. This study showed no pathological findings, with a normal 18F-FDG uptake in the spleen and bone marrow. Thus, the benign and reactive nature of the splenic and bone marrow 18F-FDG increased uptake found in the previous study was confirmed. We consider that the stimulating effect that G-CSF therapy has on the spleen and bone marrow must be taken into account when performing a 18F-FDG PET scan, as it can be an important source of false-positive results.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app