https://read.qxmd.com/read/38669811/impact-of-data-transfer-between-treatment-planning-systems-on-dosimetric-parameters
#1
JOURNAL ARTICLE
Guenda Meffe, Claudio Votta, Gabriele Turco, Elena Chillè, Matteo Nardini, Angela Romano, Giuditta Chiloiro, Giulia Panza, Matteo Galetto, Amedeo Capotosti, Roberto Moretti, Maria Antonietta Gambacorta, Luca Boldrini, Luca Indovina, Lorenzo Placidi
PURPOSE: In radiotherapy it is often necessary to transfer a patient's DICOM (Digital Imaging and COmmunications in Medicine) dataset from one system to another for re-treatment, plan-summation or registration purposes. The aim of the study is to evaluate effects of dataset transfer between treatment planning systems. MATERIALS AND METHODS: Twenty-five patients treated in a 0.35T MR-Linac (MRidian, ViewRay) for locally-advanced pancreatic cancer were enrolled. For each patient, a nominal dose distribution was optimized on the planning MRI...
April 24, 2024: Physica Medica: PM
https://read.qxmd.com/read/38664481/breakthrough-electroneutron-multi-response-miniature-dosimetry-spectrometry-in-medical-accelerator
#2
JOURNAL ARTICLE
Mehdi Sohrabi, Maryam Malekitakbolagh, Hasan Ali Nedaei
Breakthrough multi-response miniature dosimetry/spectrometry of electroneutrons (EN) was made on surface and in-depths of whole-body polyethylene phantom under 10 cm × 10 cm electron beam of 20 MV Varian Clinac 2100C electron medical accelerator commonly applied for prostate treatment. While dosimetry/spectrometry of photoneutrons (PN) has been well characterized for decades, those of ENs lagged behind due to very low EN reaction cross section and lack of sensitive neutron dosimeters/spectrometers meeting neutron dosimetry requirements...
April 25, 2024: Scientific Reports
https://read.qxmd.com/read/38663348/evaluation-of-safety-margins-for-cone-beam-ct-based-adaptive-prostate-radiotherapy
#3
JOURNAL ARTICLE
Florian Dupont, David Dechambre, Edmond Sterpin
Adaptive radiotherapy is characterized by the use of a daily imaging system, such as CBCT (Cone-Beam Computed Tomography) images to re-optimize the treatment based on the daily anatomy and position of the patient. By systematically re-delineating the Clinical Target Volume (CTV) at each fraction, target delineation uncertainty features a random component instead of a pure systematic. The goal of this work is to identify the random and systematic contributions of the delineation error and compute a new relevant Planning Target Volume (PTV) safety margin...
April 24, 2024: Physica Medica: PM
https://read.qxmd.com/read/38660134/automated-contouring-treatment-planning-and-quality-assurance-for-vmat-craniospinal-irradiation-vmat-csi
#4
JOURNAL ARTICLE
Eric Simiele, Ignacio O Romero, Jen-Yeu Wang, Yizheng Chen, Yuliia Lozko, Yuliia Severyn, Lawrie Skinner, Yong Yang, Lei Xing, Iris Gibbs, Susan M Hiniker, Nataliya Kovalchuk
PURPOSE: Create a comprehensive automated solution for pediatric and adult VMAT-CSI including contouring, planning, and plan check to reduce planning time and improve plan quality. METHODS: Seventy-seven previously treated CSI patients (age, 2-67 years) were used for creation of an auto-contouring model to segment 25 organs at risk (OARs). The auto-contoured OARs were evaluated using the Dice Similarity Coefficient (DSC), 95% Hausdorff Distance (HD95), and a qualitative ranking by one physician and one physicist (scale: 1-acceptable, 2-minor edits, 3-major edits)...
2024: Frontiers in Oncology
https://read.qxmd.com/read/38635642/assessment-of-radio-activation-using-spectroscopy-in-medical-linear-accelerators
#5
JOURNAL ARTICLE
Na Hye Kwon, Young Jae Jang, Suah Yu, Hanjin Lee, Dong Hyeok Choi, So Hyun Ahn, Kum Bae Kim, Jin Sung Kim, Dong Wook Kim, Sang Hyoun Choi
In radiotherapy, when photon energy exceeding 8 MV is utilized, photoneutrons can activate the components within the gantry of the linear accelerator (linac). At the end of the linac's lifecycle, radiation workers are tasked with its dismantling and disposal, potentially exposing them to unintentional radiation. This study aims to identify and measure the radioisotopes generated by this activation through spectroscopy, and to evaluate the effective dose rate. We selected nine medical linacs, considering various factors such as manufacturer (Siemens, Varian, and Elekta), model, energy, period of operation, and workload...
2024: PloS One
https://read.qxmd.com/read/38629051/the-gut-microbiome-and-sociability
#6
REVIEW
Katherine T Weber, Bernard J Varian, Susan E Erdman
The human gut microbiome plays an important role in the maturation of the neural, immune, and endocrine systems. Research data from animal models shows that gut microbiota communicate with the host's brain in an elaborate network of signaling pathways, including the vagus nerve. Part of the microbiome's influence extends to the behavioral and social development of its host. As a social species, a human's ability to communicate with others is imperative to their survival and quality of life. Current research explores the gut microbiota's developmental influence as well as how these gut-brain pathways can be leveraged to alleviate the social symptoms associated with various neurodevelopmental and psychiatric diseases...
2024: Frontiers in Neuroscience
https://read.qxmd.com/read/38621339/safety-and-efficacy-of-percutaneous-cryoablation-for-primary-and-metastatic-pleural-based-tumors
#7
JOURNAL ARTICLE
Erica S Alexander, Elena N Petre, Michael Offin, Marjorie Zauderer, Ken Zhao, Vlasios Sotirchos, Stephen B Solomon, Etay Ziv
PURPOSE: Assess safety and local tumor progression-free survival (LTPFS) of percutaneous cryoablation for pleural-based thoracic malignancies. MATERIALS AND METHODS: Retrospective study of 46 patients (17 treated for palliation; 9 for oligoprogression; 20 for curative intent), with 62 pleural-based thoracic lesions, treated in 59 cryoablation sessions. Patients were treated from 9/2005-11/2021 with CryoCare CS (Varian, Irvine, CA) or IceFORCE (Boston Scientific, Marlborough, MA) systems...
April 10, 2024: European Journal of Radiology
https://read.qxmd.com/read/38593826/image-quality-evaluation-of-a-new-high-performance-ring-gantry-cone-beam-computed-tomography-imager
#8
JOURNAL ARTICLE
Didier Lustermans, Gabriel Paiva Fonseca, Vicki Trier Taasti, Agustinus van de Schoot, Steven F Petit, Wouter J C van Elmpt, Frank Verhaegen
Newer cone-beam computed tomography (CBCT) imaging systems offer reconstruction algorithms including metal artifact reduction (MAR) and extended field-of-view (eFoV) techniques to improve image quality. In this study a new CBCT imager, the new Varian HyperSight CBCT, is compared to fan-beam CT and two CBCT imagers installed in a ring-gantry and C-arm linear accelerator, respectively.

Approach: The image quality was assessed for HyperSight CBCT which uses new hardware, including a large-size flat panel detector, and improved image reconstruction algorithms...
April 9, 2024: Physics in Medicine and Biology
https://read.qxmd.com/read/38569013/assessing-the-sensitivity-and-suitability-of-a-range-of-detectors-for-simt-psqa
#9
JOURNAL ARTICLE
Leon Dunn, Alessia Tamborriello, Brindha Subramanian, Xiaolei Xu, Tyrone Te Ruruku
PURPOSE: Single-isocenter multi-target intracranial stereotactic radiotherapy (SIMT) is an effective treatment for brain metastases with complex treatment plans and delivery optimization necessitating rigorous quality assurance. This work aims to assess five methods for quality assurance of SIMT treatment plans in terms of their suitability and sensitivity to delivery errors. METHODS: Sun Nuclear ArcCHECK and SRS MapCHECK, GafChromic EBT Radiochromic Film, machine log files, and Varian Portal Dosimetry were all used to measure 15 variations of a single SIMT plan...
April 3, 2024: Journal of Applied Clinical Medical Physics
https://read.qxmd.com/read/38556402/comparative-analysis-of-two-dose-volume-histogram-prediction-tools-for-treatment-planning-in-volumetric-modulated-arc-therapy-a-multi-planner-study
#10
JOURNAL ARTICLE
Motoharu Sasaki, Yuji Nakaguchi, Takeshi Kamomae, Akira Tsuzuki, Soma Sawada, Koki Shibuya, Masataka Oita, Masahide Tominaga, Yuki Tominaga, Hitoshi Ikushima
The increase in high-precision radiation therapy, particularly volumetric-modulated arc therapy (VMAT), has increased patient numbers and expanded treatment sites. However, a significant challenge in VMAT treatment planning is the inconsistent plan quality among different planners and facilities. This study explored the use of dose-volume histogram (DVH) prediction tools to address these disparities, specifically focusing on RapidPlan (Varian Medical Systems) and PlanIQ (Sun Nuclear). RapidPlan predicts achievable DVHs and automatically generates optimization objectives...
March 30, 2024: Medical Dosimetry: Official Journal of the American Association of Medical Dosimetrists
https://read.qxmd.com/read/38556165/retrospective-study-evaluating-dental-side-effects-of-radiotherapy-in-patients-treated-for-head-and-neck-cancer
#11
JOURNAL ARTICLE
Y Karaca, S Beauvois, M Paesmans, Z Mokhtari, D Dequanter, C Al Wardi, L Evrard, D Van Gestel
INTRODUCTION: Head and neck cancer squamous cell carcinoma (HNSCC) is the seventh most common cancer worldwide with around 600000 new diagnosis each year. Nowadays, in locally advanced disease, radiotherapy (RT) play an important role, this with or without chemotherapy in organ preservation strategies. More specific for early stage localized disease, RT (or surgery) seems to give similar results on locoregional control (LRC) and choice is made according to the organ preservation issue...
March 29, 2024: Journal of Stomatology, Oral and Maxillofacial Surgery
https://read.qxmd.com/read/38554351/challenges-in-commissioning-the-tset-technique-a-new-approach-towards-monitor-unit-calculation-and-beam-profile-measurements
#12
JOURNAL ARTICLE
Gaurav Trivedi, Arun S Oinam, Budhi Singh Yadav, Pushpendra P Singh, Ranjit Singh, Ngangom Robert
INTRODUCTION: Total skin electron beam therapy, commonly known as TSET, is a good choice of treatment for patients suffering from mycosis fungoides. The aim of this study was to introduce a new approach to the beam profile measurement using diodes and to calculate the monitor units required for the TSET treatment by the use of a simple setup of output measurement. Dosimetric measurements required for the treatment were taken to establish the Stanford technique in the department, and the measured data was compared with the published data...
January 1, 2024: Journal of Cancer Research and Therapeutics
https://read.qxmd.com/read/38551392/comprehensive-beam-delivery-latency-evaluation-for-gated-proton-therapy-system-using-customized-multi-channel-signal-acquisition-platform
#13
JOURNAL ARTICLE
Zhipeng Liu, Lingjing Pan, Tao Ma, Hsiao-Ming Lu, Yuanyuan Wang
PURPOSE: Beam delivery latency in respiratory-gated particle therapy systems is a crucial issue to dose delivery accuracy. The aim of this study is to develop a multi-channel signal acquisition platform for investigating gating latencies occurring within RPM respiratory gating system (Varian, USA) and ProBeam proton treatment system (Varian, USA) individually. METHODS: The multi-channel signal acquisition platform consisted of several electronic components, including a string position sensor for target motion detection, a photodiode for proton beam sensing, an interfacing board for accessing the trigger signal between the respiratory gating system and the proton treatment system, a signal acquisition device for sampling and synchronizing signals from the aforementioned components, and a laptop for controlling the signal acquisition device and data storage...
March 29, 2024: Journal of Applied Clinical Medical Physics
https://read.qxmd.com/read/38550495/dose-painting-linear-accelerator-radiosurgery-of-glomus-jugulare-with-dosimetric-comparison-to-gamma-knife
#14
JOURNAL ARTICLE
Alessandro Valderrama, Long Di, Elizabeth Bossart, Adrien A Eshraghi, Eric A Mellon
Objectives In this study, we outline our rationale for delivering a dose of ≥15 Gy in stereotactic radiosurgery (SRS) of glomus jugulare tumor (GJT) while ensuring the avoidance of complications associated with doses >13 Gy to the facial nerve. To avoid such complications, we initially utilized the Gamma Knife Perfexion (GK) system (Elekta Instrument AB, Stockholm, Sweden) at our institution but encountered challenges related to lengthy treatment times and difficulty in sculpting doses to minimize doses to spare the facial nerve...
February 2024: Curēus
https://read.qxmd.com/read/38547546/integrating-cine-epid-dynamic-delivery-and-the-off-axis-winston-lutz-test-to-enhance-quality-control-in-multiple-brain-metastasis-stereotactic-radiotherapy
#15
JOURNAL ARTICLE
Paul Retif, Abdourahamane Djibo Sidikou, Alexandre Waltener, Romain Letellier, Anwar Al Salah, Estelle Pfletschinger, Fabian Taesch, Emilie Verrecchia-Ramos, Xavier Michel
PURPOSE: Stereotactic radiotherapy (SRT) has transformed cancer treatment, especially for brain metastases. Ensuring accurate SRT delivery is crucial, with the Winston-Lutz test being an important quality control tool. Off-axis Winston-Lutz (OAWL) tests are designed for accuracy assessment, but most are limited to fixed angles and hampered by local-field shifts caused by suboptimal Multi-Leaf Collimator (MLC) positioning. This study introduces a new OAWL approach for quality control in multi-brain-metastasis SRT...
March 27, 2024: Physica Medica: PM
https://read.qxmd.com/read/38539544/clinical-workflow-of-cone-beam-computer-tomography-based-daily-online-adaptive-radiotherapy-with-offline-magnetic-resonance-guidance-the-modular-adaptive-radiotherapy-system-mars
#16
JOURNAL ARTICLE
Ji-Young Kim, Bouchra Tawk, Maximilian Knoll, Philipp Hoegen-Saßmannshausen, Jakob Liermann, Peter E Huber, Mona Lifferth, Clemens Lang, Peter Häring, Regula Gnirs, Oliver Jäkel, Heinz-Peter Schlemmer, Jürgen Debus, Juliane Hörner-Rieber, Fabian Weykamp
PURPOSE: The Ethos (Varian Medical Systems) radiotherapy device combines semi-automated anatomy detection and plan generation for cone beam computer tomography (CBCT)-based daily online adaptive radiotherapy (oART). However, CBCT offers less soft tissue contrast than magnetic resonance imaging (MRI). This work aims to present the clinical workflow of CBCT-based oART with shuttle-based offline MR guidance. METHODS: From February to November 2023, 31 patients underwent radiotherapy on the Ethos (Varian, Palo Alto, CA, USA) system with machine learning (ML)-supported daily oART...
March 19, 2024: Cancers
https://read.qxmd.com/read/38520072/acr-benchmark-testing-of-a-novel-high-speed-ring-gantry-linac-kv-cbct-system
#17
JOURNAL ARTICLE
Allison Haertter, Michael Salerno, Brandon Koger, Christopher Kennedy, Michelle Alonso-Basanta, Lei Dong, Boon-Keng Teo, Taoran Li
A new generation cone-beam computed tomography (CBCT) system with new hardware design and advanced image reconstruction algorithms is available for radiation treatment simulation or adaptive radiotherapy (HyperSight CBCT imaging solution, Varian Medical Systems-a Siemens Healthineers company). This study assesses the CBCT image quality metrics using the criteria routinely used for diagnostic CT scanner accreditation as a first step towards the future use of HyperSight CBCT images for treatment planning and target/organ delineations...
March 22, 2024: Journal of Applied Clinical Medical Physics
https://read.qxmd.com/read/38518877/harvesting-marine-microalgae-tetraselmis-sp-using-cellulose-acetate-membrane
#18
JOURNAL ARTICLE
Afrillia Fahrina, Fahrurrozi Fahrurrozi, Hendra Munandar, Varian Fahmi, Sutarat Thongratkaew, Kajornsak Faungnawakij, Muhammad Roil Bilad
This study presents the development and application of a cellulose acetate phase-inversion membrane for the efficient harvesting of Tetraselmis sp., a promising alternative for aquaculture feedstock. Once fabricated, the cellulose acetate membrane was characterized, and its performance was evaluated through the filtration of Tetraselmis sp. broth. The results demonstrated that the developed membrane exhibited exceptional microalgae harvesting efficiency. It showed a low intrinsic resistance and a high clean water permeability of 1100 L/(m2 ·h·bar), enabling high-throughput filtration of Tetraselmis sp...
March 20, 2024: Bioresource Technology
https://read.qxmd.com/read/38515394/peripheral-doses-beyond-electron-applicators-in-conventional-c-arm-linear-accelerators-a-systematic-literature-review
#19
REVIEW
Kapil Dev Maharaj, Joshua Dass, Mounir Ibrahim, Talat Mahmood, Pejman Rowshanfarzad
Background: This review investigates peripheral dose levels in electron beam treatments, comparing different manufacturers including Varian, Elekta, and Siemens. Accurate measurement of peripheral dose is vital for patient safety and precise radiation delivery in radiation therapy. Methods: This review followed PRISMA standards, conducting a comprehensive literature search from 1978 to July 2023. Emphasis was on identifying studies analyzing peripheral doses related to various electron beam energies, beam angle, field sizes, cutouts, and applicator combinations...
2024: Technology in Cancer Research & Treatment
https://read.qxmd.com/read/38513476/study-on-induced-radioactivity-and-individual-dose-evaluation-in-gantry-room-for-varian-probeam-proton-therapy-system
#20
JOURNAL ARTICLE
Changli Luo, Wuyuan Li, Yang Li, Xilong Han, Bo Yang, Youwu Su, Shakhboz Khasanov, Xuebo Liu, Wang Mao, Weiwei Yan
Proton therapy has emerged as an advantageous modality for tumor radiotherapy due to its favorable physical and biological properties. However, this therapy generates induced radioactivity through nuclear reactions between the primary beam, secondary particles, and surrounding materials. This study focuses on systematically investigating the induced radioactivity in the gantry room during pencil beam scanning, utilizing both experimental measurements and Monte Carlo simulations. Results indicate that patients are the primary source of induced radioactivity, predominantly producing radionuclides such as 11 C, 13 N, and 15 O...
March 19, 2024: Applied Radiation and Isotopes
keyword
keyword
47924
1
2
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.