keyword
https://read.qxmd.com/read/38673699/alterations-in-corneal-sensitivity-staining-and-biomechanics-of-alopecia-areata-patients-novel-findings-in-a-case-control-study
#1
JOURNAL ARTICLE
Barbara Burgos-Blasco, Patricia Burgos-Blasco, Olivia Rodriguez-Quet, Pedro Arriola-Villalobos, Jose Ignacio Fernandez-Vigo, David Saceda-Corralo, Sergio Vaño-Galvan, Julián García-Feijóo
Background : A higher prevalence of ophthalmological alterations in systemic inflammatory diseases has been demonstrated. Objectives : Our objectives were to determine anterior segment findings and corneal properties in alopecia areata (AA). Methods : This is a case-control study. Severe AA patients (Severity of Alopecia Tool > 50%) and non-AA subjects underwent a general ophthalmological examination, a Pentacam and Corvis scheimpflug technology examination (Oculus Optikgeräte GmbH, Wetzlar, Germany)...
April 21, 2024: Journal of Clinical Medicine
https://read.qxmd.com/read/38654988/biomechanical-changes-in-keratoconus-after-customized-stromal-augmentation
#2
Sana Niazi, Jorge Alió Del Barrio, Farideh Doroodgar, Azad Sanginabadi, Cyrus Alinia, Seyed Javad Hashemian, Hassan Hashemi, Jorge L Alio
PURPOSE: To verify corneal biomechanical changes, poststromal augmentation using myopic small-incision lenticule extraction's (SMILEs) lenticules in advanced keratoconus (KCN) through Corvis ST (Oculus, Wetzlar, Germany). MATERIALS AND METHODS: A clinical trial enrolled 22 advanced KCN patients. We implanted lenticules exceeding 100 μ according to a nomogram and evaluated biomechanical factors through Corvis ST at 3-, 6-, and 24-month postimplantation. We examined parameters during the first applanation (A1), second applanation (A2), highest concavity (HC)/max concavity events, and Vinciguerra screening parameters, as recently established criteria derived from the ideal blend of diverse biomechanical and ocular factors and formulated through the application of logistic regression...
2024: Taiwan Journal of Ophthalmology
https://read.qxmd.com/read/38648457/evaluation-of-dynamic-corneal-response-parameters-and-the-biomechanical-e-staging-after-intacs%C3%A2-sk-implantation-in-keratoconus
#3
JOURNAL ARTICLE
Elias Flockerzi, Tim Berger, Berthold Seitz, Loic Hamon, Loay Daas
PURPOSE: This retrospective longitudinal study evaluated the biomechanical E-staging in KC corneas before and after intracorneal ring segment (ICRS) implantation (Intacs® SK, Addition Technology, Illinois, United States). METHODS: Biomechanical E-staging for ectatic corneal diseases was applied retrospectively on 49 KC corneas of 41 patients who underwent ICRS implantation. The main outcome parameters included the Corvis Biomechanical Factor (CBiF, the linearized Corvis Biomechanical Index and the biomechanical parameters included), the resulting biomechanical E-staging, the stress-strain index, thinnest corneal thickness (TCT), maximal anterior keratometry (Kmax), and the anterior radius of curvature (ARC)...
May 1, 2024: Indian Journal of Ophthalmology
https://read.qxmd.com/read/38629736/a-new-biomechanical-deformation-response-parameter-change-in-central-corneal-thickness-during-air-puff-induced-corneal-deformation
#4
JOURNAL ARTICLE
Monica D Okon, Yanhui Ma, B Audrey Nguyen-Rudy, Cynthia J Roberts
PURPOSE: To investigate the percent change in central corneal thickness (%ΔCCT) during air-puff-induced deformation as an indicator of corneal biomechanical response. METHODS: Forty ex vivo human eyes from forty donors were imaged using the CorVis ST at experimentally controlled intraocular pressure (IOP) of 10, 20, 30, and 40 mmHg, followed by uniaxial strip testing to calculate tensile modulus. The CorVis ST research software tracked the anterior and posterior cornea edges and determined the dynamic corneal response (DCR) parameters...
April 17, 2024: Current Eye Research
https://read.qxmd.com/read/38558790/effect-of-corneal-cross-linking-on-biomechanical-changes-following-transepithelial-photorefractive-keratectomy-and-femtosecond-laser-assisted-lasik
#5
JOURNAL ARTICLE
Wen Chen, FangJun Bao, Cynthia J Roberts, Jia Zhang, Chong Wang, XueFei Li, JunJie Wang, Anas Ziad Masoud Abu Said, Kevin Nguelemo Mayopa, YaNi Chen, XiaoBo Zheng, Ashkan Eliasy, Ahmed Elsheikh, ShiHao Chen
Purpose: To evaluate the change in corneal biomechanics in patients with postoperative ectasia risk when combining two common laser vision correction procedures (tPRK and FS-LASIK) with cross-linking (in tPRK Xtra and FS-LASIK Xtra). Methods: The study included 143 eyes of 143 myopic, astigmatic patients that were divided into non-cross-linked refractive surgery groups (non-Xtra groups, tPRK and FS-LASIK) and cross-linked groups (Xtra groups, tPRK Xtra and FS-LASIK Xtra) according to an ectasia risk scoring system...
2024: Frontiers in Bioengineering and Biotechnology
https://read.qxmd.com/read/38556185/corneal-biomechanical-characteristics-in-myopes-and-emmetropes-measured-by-corvis-st-a-meta-analysis
#6
REVIEW
Min-Xin Liu, Ke-Yao Zhu, Dan-Lin Li, Xing-Xuan Dong, Gang Liang, Andrzej Grzybowski, Chen-Wei Pan
PURPOSE: To comprehensively identify the corneal biomechanical differences measured by Corvis ST between different degrees of myopia and emmetropia. DESIGN: Systematic review and meta-analysis. METHODS: Electronic databases, including PubMed, Embase, and Web of Science, were systematically searched for studies comparing the corneal biomechanics among various degrees of myopes and emmetropes using Corvis ST. The weighted mean differences and 95% confidence intervals were calculated...
March 29, 2024: American Journal of Ophthalmology
https://read.qxmd.com/read/38534495/mendelian-randomisation-analysis-of-causal-association-between-lifestyle-health-factors-and-keratoconus
#7
JOURNAL ARTICLE
Jiaxuan Cheng, Lanting Yang, Yishan Ye, Lvfu He, Shihao Chen, Junjie Wang
Keratoconus (KC), a leading cause of vision impairment, has an unclear aetiology. This study used Mendelian randomization (MR) to explore the causal links between various factors (smoking, asthma, Down syndrome, inflammatory bowel disease, atopic dermatitis, and serum 25-hydroxyvitamin D levels) and KC. A two-sample MR design, grounded in genome-wide association study (GWAS) summary statistics, was adopted using data from FinnGen, UK Biobank, and other GWAS-related articles. The inverse-variance weighted (IVW) method was employed, complemented by the Wald ratio method for factors with only one single-nucleotide polymorphism (SNP)...
February 26, 2024: Bioengineering
https://read.qxmd.com/read/38529005/characterization-of-corneal-biomechanics-using-corvis-st-device-in-different-grades-of-myopia-in-a-sample-of-middle-eastern-ethnicity
#8
JOURNAL ARTICLE
Esraa El-Mayah, Ahmed Saad Albalkini, Omar A Barrada
PURPOSE: To characterize corneal biomechanical properties using the CORVIS-ST device in myopic individuals. METHODS: This prospective cross-sectional study included patients with myopia. Our study included 154 eyes of 154 myopic patients aged between 18 and 40 years, with stable refraction for at least 2 years. A full ophthalmological examination and corneal tomography were performed using a Pentacam HR device. Corneal biomechanical parameters were assessed using the CORVIS-ST device in mild, moderate, severe, and extreme myopia groups...
2024: Clinical Ophthalmology
https://read.qxmd.com/read/38524314/corneal-stress-strain-index-in-myopic-indian-population
#9
JOURNAL ARTICLE
Vaishal P Kenia, Raj V Kenia, Pradnya Bendre, Onkar H Pirdankar
AIM: The purpose is to study the corneal stress-strain index (SSI) in myopic refractive error among Indian subjects. METHODS: A retrospective study where young myopic subjects aged between 11 and 35 years who had undergone corneal biomechanics assessment using Corvis ST between January 2017 and December 2021 were enrolled. Subjects with central corneal thickness (CCT) <500 μ, intraocular pressure (IOP) >21 mmHg, history of any systemic and ocular disease or any previous ocular surgery, high astigmatism, corneal disease such as keratoconus were excluded...
2024: Oman Journal of Ophthalmology
https://read.qxmd.com/read/38502381/corneal-biomechanics-and-their-association-with-severity-of-lens-dislocation-in-marfan-syndrome
#10
JOURNAL ARTICLE
Guangming Jin, Minjie Zou, Longhui Li, Zhenzhen Liu, Charlotte Young, Haotian Qi, Danying Zheng
PURPOSE: To investigate corneal biomechanical properties and its associations with the severity of lens dislocation in patients with Marfan syndrome. METHODS: A total of 30 patients with Marfan syndrome and 30 age-, sex- and axial length (AL)-matched controls were recruited. Corneal biomechanical parameters of both groups were measured by CorVis ST and were compared between groups. Potential associations between corneal biomechanical parameters and severity of lens dislocation were also investigated...
March 19, 2024: International Ophthalmology
https://read.qxmd.com/read/38493602/cornet-autonomous-feature-learning-in-raw-corvis-st-data-for-keratoconus-diagnosis-via-residual-cnn-approach
#11
JOURNAL ARTICLE
PeiPei Zhang, LanTing Yang, YiCheng Mao, XinYu Zhang, JiaXuan Cheng, YuanYuan Miao, FangJun Bao, ShiHao Chen, QinXiang Zheng, JunJie Wang
PURPOSE: To ascertain whether the integration of raw Corvis ST data with an end-to-end CNN can enhance the diagnosis of keratoconus (KC). METHOD: The Corvis ST is a non-contact device for in vivo measurement of corneal biomechanics. The CorNet was trained and validated on a dataset consisting of 1786 Corvis ST raw data from 1112 normal eyes and 674 KC eyes. Each raw data consists of the anterior and posterior corneal surface elevation during air-puff induced dynamic deformation...
March 13, 2024: Computers in Biology and Medicine
https://read.qxmd.com/read/38492897/a-special-issue-dedicated-to-the-2022-meeting-of-the-french-society-for-nanomedicine
#12
EDITORIAL
Lucie Sancey, Yohann Corvis, Sylvie Begin-Colin, Nicolas Tsapis
No abstract text is available yet for this article.
March 14, 2024: International Journal of Pharmaceutics
https://read.qxmd.com/read/38441857/effect-of-intraorbital-mechanical-compression-on-retinal-microvascular-perfusion-in-quiescent-thyroid-associated-ophthalmopathy-based-on-ocular-biomechanics-measured-by-corvis-st
#13
JOURNAL ARTICLE
Wei Fang, Ziyun Zhou, Zhenbin Qian, Mengdi Wang, Fangjun Bao, Lijun Shen
INTRODUCTION: To analyze the correlation between orbital compliance and retinal vessel density (VD) based on dynamic Scheimpflug analyzer (Corvis ST) and optical coherence tomographic angiography (OCT-A). METHODS: In this prospective observational study, 65 eyes of 44 patients with thyroid-associated ophthalmopathy (TAO) in quiescent stage were included (15 males and 29 females). The whole eye movement (WEM) was detected by Corvis ST. The superficial capillary plexus VD (SCP-VD) and deep capillary plexus VD (DCP-VD) were obtained by scanning the 3 × 3 mm area around the fovea using OCT-A, while the peripapillary vessel density (ppVD) was obtained by scanning the 4...
March 5, 2024: Ophthalmology and Therapy
https://read.qxmd.com/read/38410632/scheimpflug-based-corneal-biomechanical-analysis-as-a-predictor-of-glaucoma-in-eyes-with-high-myopia
#14
JOURNAL ARTICLE
Pedro M L Baptista, André S Ferreira, Nisa P Silva, Ana R M Figueiredo, Isabel C Sampaio, Rita V F Reis, Renato Ambrósio, Pedro M A M Menéres, João N M Beirão, Maria J F S Menéres
PURPOSE: To address if corneal biomechanical behavior has a predictive value for the presence of glaucomatous optical neuropathy in eyes with high myopia. PATIENTS AND METHODS: This observational cross-sectional study included 209 eyes from 108 consecutive patients, divided into four groups: high myopia and primary open-angle glaucoma (POAG) - HMG, n = 53; high myopia without POAG - HMNG, n = 53; non-myopic with POAG - POAG, n = 50; non-myopic and non-POAG- NMNG, n = 53...
2024: Clinical Ophthalmology
https://read.qxmd.com/read/38403983/the-statistical-fragility-of-marrow-stimulation-for-cartilage-defects-of-the-knee-a-systematic-review-of-randomized-controlled-trials
#15
JOURNAL ARTICLE
Avanish Yendluri, Ara Alexanian, Rohit R Chari, John J Corvi, Nikan K Namiri, Junho Song, Michael J Alaia, Xinning Li, Robert L Parisien
OBJECTIVE: Marrow stimulation is used to address knee cartilage defects. In this study, we used the fragility index (FI), reverse fragility index (rFI), and fragility quotient (FQ) to evaluate statistical fragility of outcomes reported in randomized controlled trials (RCTs) evaluating marrow stimulation. DESIGN: PubMed, Embase, and MEDLINE were queried for recent RCTs (January 1, 2010-September 5, 2023) assessing marrow stimulation for cartilage defects of the knee...
February 25, 2024: Cartilage
https://read.qxmd.com/read/38402288/corneal-stress%C3%A2-strain-index-in-relation-to-retinal-nerve-fibre-layer-thickness-among-healthy-young-adults
#16
JOURNAL ARTICLE
Min-Xin Liu, Dan-Lin Li, Zhi-Jian Yin, Yue-Zu Li, Ya-Jie Zheng, Yu Qin, Rong Ma, Gang Liang, Chen-Wei Pan
BACKGROUND/OBJECTIVES: To determine the relationship between corneal stress-strain index (SSI) and retinal nerve fibre layer (RNFL) thickness. SUBJECTS/METHODS: 1645 healthy university students from a university-based study contributed to the analysis. The RNFL thickness was measured by high-definition optical coherence tomography (HD-OCT), axial length (AL) was measured by IOL Master, and corneal biomechanics including SSI, biomechanical corrected intraocular pressure (bIOP), and central corneal thickness (CCT) were measured by Corvis ST...
February 24, 2024: Eye
https://read.qxmd.com/read/38382278/biometric-and-corneal-characteristics-in-marfan-syndrome-with-ectopia-lentis
#17
JOURNAL ARTICLE
L Izquierdo, I Gomez, C Moctezuma, M Mannis, M A Henriquez
PURPOSE: To describe the biometric and corneal characteristics of patients with Marfan Syndrome (MFS) and ectopia lentis. STUDY DESIGN: Observational, descriptive, prospective study. Subjects Individuals with MFS with ectopia lentis (EL). METHODS: Fourty-four eyes of 23 patients underwent Scheimpflug analysis using the Pentacam (Oculus, Wetzlar, Germany), axial length (AL) using the IOL master 700 (Carl Zeiss AG, Oberkochen, Germany), endothelial cell count (ECC) using the CEM-350 (NIDEK, Maihama, Japan) and corneal biomechanics evaluation with the Ocular Response Analyzer: ORA (Reichert Ophthalmic Instruments, Buffalo, New York, USA) and Corvis (Oculus, Wetzlar, Germany)...
February 20, 2024: Journal Français D'ophtalmologie
https://read.qxmd.com/read/38361411/evaluating-the-daily-modulation-of-fadd-and-related-molecular-markers-in-different-brain-regions-in-male-rats
#18
JOURNAL ARTICLE
Fernando Yáñez-Gómez, Laura Gálvez-Melero, Sandra Ledesma-Corvi, Cristian Bis-Humbert, Elena Hernández-Hernández, Glòria Salort, Rubén García-Cabrerizo, M Julia García-Fuster
Fas-Associated protein with Death Domain (FADD), a key molecule controlling cell fate by balancing apoptotic versus non-apoptotic functions, is dysregulated in post-mortem brains of subjects with psychopathologies, in animal models capturing certain aspects of these disorders, and by several pharmacological agents. Since persistent disruptions in normal functioning of daily rhythms are linked with these conditions, oscillations over time of key biomarkers, such as FADD, could play a crucial role in balancing the clinical outcome...
February 2024: Journal of Neuroscience Research
https://read.qxmd.com/read/38342901/distribution-and-determinants-of-corneal-volume-among-healthy-young-chinese-adults-a-cross-sectional-study
#19
JOURNAL ARTICLE
Gang Liang, Jia-Yan Kai, Dan-Lin Li, Zhi-Jian Yin, Yue-Zu Li, Rong Ma, Ya-Jie Zheng, Yu Qin, Chen-Wei Pan
BACKGROUND: Several studies have previously reported the normal values of corneal volume (CV) in various populations, whereas little is known about the CV distribution in healthy young Chinese adults. Our study aimed to investigate the distribution of CV and its relationships with other ocular biometric parameters among healthy young Chinese adults. METHODS: A total of 1645 eyes from 1645 students at Dali University in Yunnan Province, China, were analyzed. Pentacam was used to measure CV...
February 12, 2024: BMC Ophthalmology
https://read.qxmd.com/read/38334467/altered-corneal-biomechanics-according-to-the-biomechanical-e-staging-in-pellucid-marginal-degeneration
#20
JOURNAL ARTICLE
Burak Mergen, Haris Sideroudi, Berthold Seitz, Elias Flockerzi
PURPOSE: The purpose of this study was to investigate corneal biomechanics in pellucid marginal degeneration (PMD) compared with healthy controls using Corvis ST (Oculus, Germany) by using the new biomechanical E-staging (based on the Corvis Biomechanical Factor, the linearized Corvis Biomechanical Index) together with tomographic parameters. METHODS: Corneal biomechanical and topographic data of 75 eyes of 75 patients with PMD and 75 eyes of 75 age-matched and sex-matched healthy controls were investigated...
February 6, 2024: Cornea
keyword
keyword
169276
1
2
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.