keyword
https://read.qxmd.com/read/38649919/is-ai-3d-printed-psi-an-accurate-option-for-patients-with-developmental-dysplasia-of-the-hip-undergoing-tha
#1
JOURNAL ARTICLE
Han Zheng, Eryou Feng, Yao Xiao, Xingyu Liu, Tianyu Lai, Zhibiao Xu, Jingqiao Chen, Shiwei Xie, Feitai Lin, Yiling Zhang
BACKGROUND: In traditional surgical procedures, significant discrepancies are often observed between the pre-planned templated implant sizes and the actual sizes used, particularly in patients with congenital hip dysplasia. These discrepancies arise not only in preoperative planning but also in the precision of implant placement, especially concerning the acetabular component. Our study aims to enhance the accuracy of implant placement during Total Hip Arthroplasty (THA) by integrating AI-enhanced preoperative planning with Patient-Specific Instrumentation (PSI)...
April 22, 2024: BMC Musculoskeletal Disorders
https://read.qxmd.com/read/38601198/the-lancet-robotic-system-can-improve-surgical-efficiency-in-total-hip-arthroplasty-a-prospective-randomized-multicenter-parallel-controlled-clinical-trial
#2
JOURNAL ARTICLE
Zhihong Xu, Senlin Chai, Dongyang Chen, Weijun Wang, Jin Dai, Xiaofeng Zhang, Jianghui Qin, Kai Song, Xinhua Li, Jing Han, Qing Chang, Miaofeng Zhang, Chenxi Xue, Jun Lu, Lidong Wu, Yunfeng Yao, Lan Li, Qing Jiang
OBJECTIVE: To evaluate the accuracy and safety of the LANCET robotic system, a robot arm assisted operation system for total hip arthroplasty via a multicenter clinical randomized controlled trial. METHODS: A total of 116 patients were randomized into two groups: LANCET robotic arm assisted THA group (N = 58) and the conventional THA group (N = 58). General information about the patients was collected preoperatively. Operational time and bleeding were recorded during the surgery...
March 2024: Journal of Orthopaedic Translation
https://read.qxmd.com/read/38572714/reliability-of-the-transverse-acetabular-ligament-as-a-landmark-for-functional-cup-anteversion-in-total-hip-arthroplasty
#3
JOURNAL ARTICLE
Shivan S Jassim, Tejasvi Bhatia, Jack R D McMahon, Jim W Pierrepont, Stephen J McMahon
BACKGROUND: The transverse acetabular ligament (TAL) can be a useful and reproducible landmark in the orientation of the acetabular cup in total hip arthroplasty (THA). Its role in guiding cup orientation when aiming to implant in a functional anteversion orientation is unclear. The aim of this study was to assess the relationship between the TAL and the planned acetabular cup anteversion when implanted in a function orientation. MATERIAL AND METHODS: In a retrospective study the anteversion of the TAL in the contralateral un-replaced hip was measured in CT scans of patients undergoing THA and compared to the functional cup anteversion using the patient-specific spinopelvic parameters...
April 4, 2024: Hip International: the Journal of Clinical and Experimental Research on Hip Pathology and Therapy
https://read.qxmd.com/read/38191491/imageless-navigation-system-naviswiss-provides-accurate-component-position-in-total-hip-arthroplasty-with-lateral-decubitus-position-for-end-stage-hip-osteoarthritis-a-prospective-cohort-study-with-ct-validation
#4
JOURNAL ARTICLE
Corey J Scholes, Manaal Fatima, Tobias Schwagli, David Liu
AIMS: The Naviswiss system (Naviswiss AG, Brugg, Switzerland) is a handheld imageless navigation device used to improve the accuracy of implant positioning in total hip arthroplasty (THA). However, clinical data for leg length discrepancy and femoral offset is lacking, and the validity of the system has not been reported for patients undergoing THA in the lateral decubitus position. This study aimed to report the accuracy of the device in this patient population. METHODS: Patients underwent THA in the lateral decubitus position performed by a single surgeon...
January 8, 2024: Arthroplasty
https://read.qxmd.com/read/38073750/evaluating-the-effectiveness-of-conventional-prostheses-against-dual-mobility-prostheses-in-the-treatment-of-femoral-neck-fractures-in-two-separate-groups-of-patients-a-clinical-trial-study
#5
JOURNAL ARTICLE
Mohammad Parhamfar, Alireza Hosseini, Mostafa Khashei, Mehdi Motififard, Amirmohammad Taravati, Somayeh Shirazinejad, Ali Afsharirad, Amirhossein Sadeghian, Ali Sherafati Chaleshtori
BACKGROUND: Femoral neck fracture is a common posttraumatic injury in the elderly. Currently, orthopedic surgeons conducting total hip arthroplasty (THA) for hip fractures have various prosthetic alternatives. Dual-mobility cup THA is recommended for hip fracture patients to reduce prosthesis dislocation. Therefore, the goal of this research is to evaluate the effectiveness of conventional prostheses against dual-mobility prostheses in treating femoral neck fractures in two groups of patients...
2023: Advanced Biomedical Research
https://read.qxmd.com/read/37957756/quantifying-anterior-pelvic-roll-during-total-hip-arthroplasty-in-the-lateral-decubitus-position
#6
JOURNAL ARTICLE
Andrew P Kurmis, Ernest C Lourens
BACKGROUND: Unintended pelvic positional change is an acknowledged intra-operative problem for hip arthroplasty, seen commonly with procedures performed in the lateral position. If unrecognised, such changes can dramatically alter final acetabular component anteversion potentially resulting in suboptimal construct performance. It has previously been suggested that pelvic roll of just 13° may be enough to place an otherwise perfectly orientated cup outside of conventional ± 10° safe zones...
November 14, 2023: Journal of Orthopaedic Surgery and Research
https://read.qxmd.com/read/37727965/defining-the-optimal-position-of-the-lipped-liner-in-combination-with-cup-orientation-and-stem-version
#7
JOURNAL ARTICLE
Alessandro Navacchia, Joseph Pagkalos, Edward T Davis
AIMS: The aim of this study was to identify the optimal lip position for total hip arthroplasties (THAs) using a lipped liner. There is a lack of consensus on the optimal position, with substantial variability in surgeon practice. METHODS: A model of a THA was developed using a 20° lipped liner. Kinematic analyses included a physiological range of motion (ROM) analysis and a provocative dislocation manoeuvre analysis. ROM prior to impingement was calculated and, in impingement scenarios, the travel distance prior to dislocation was assessed...
September 20, 2023: Bone & Joint Research
https://read.qxmd.com/read/36934286/fully-constrained-acetabular-liner-vs-dual-mobility-hip-joint-in-the-surgical-treatment-of-metastatic-bone-disease-of-the-hip-study-protocol-for-a-randomized-open-label-two-arm-non-inferiority-trial-evaluating-the-post-operative-hip-dislocation-rate
#8
JOURNAL ARTICLE
Afrim Iljazi, Michala Skovlund Sørensen, Kolja Sebastian Weber, Allan Villadsen, Frank Eriksson, Michael Mørk Petersen
BACKGROUND: Patients receiving total hip arthroplasty (THA) due to metastatic bone disease of the hip (MBD) are at an increased risk of post-operative joint dislocation compared to other populations. Different joint solutions have been developed with the purpose of reducing the dislocation risk compared to regular THAs. One of these solutions, the constrained liner (CL), has been used increasingly at our department in recent years. This design, however, is prone to polyethylene wear and higher revision rates...
March 18, 2023: Trials
https://read.qxmd.com/read/36777120/does-intra-operative%C3%A2-fluoroscopy-significantly-improve-component-position-in-a-primary-total-hip-arthroplasty-our-experience-in-a-tertiary-care-hospital
#9
JOURNAL ARTICLE
Manan Shah, Alfven Vieira, Akshay Mahajan, Laksh Agrawal, Dhruv Shah, Shahish Surme, Ameya Velankar
BACKGROUND: Optimal component placement, equalization of leg lengths, and recreation of offset are important surgical objectives during total hip arthroplasty (THA). Historically, many surgeons have aimed for the Lewinnek's " safe zone," which is defined as 30°-50° of abduction and 5°-25° of anteversion. Methods for optimizing cup position include anatomic landmarks, room landmarks, acetabular cup coverage, and ischial or pubis palpation...
February 2023: Indian Journal of Orthopaedics
https://read.qxmd.com/read/36725766/comparison-of-single-taper-and-dual-taper-versions-of-the-same-stem-design-in-total-hip-arthroplasty-for-primary-osteoarthritis
#10
JOURNAL ARTICLE
Francesco Castagnini, Barbara Bordini, Monica Cosentino, Enrico Tassinari, Giulia Guizzardi, Francesco Traina
BACKGROUND: In total hip arthroplasty (THA), the outcomes of single taper (ST) and dual taper (DT) versions of the same stem design have been scarcely studied. A registry study comparing ST and DT versions of the same stem design was designed, aiming to assess: (1) the survival rates and the hazard ratios for failure; (2) the survival rates and the hazard ratios for failure using stem-focused endpoints. MATERIAL AND METHODS: A regional arthroplasty registry was interrogated about stem designs with ST and DT versions in cementless THAs performed for primary osteoarthritis...
February 1, 2023: Journal of Orthopaedics and Traumatology: Official Journal of the Italian Society of Orthopaedics and Traumatology
https://read.qxmd.com/read/36601608/transitioning-from-the-posterior-approach-to-the-direct-anterior-approach-for-total-hip-arthroplasty
#11
JOURNAL ARTICLE
Cameron M Metzger, Hassan Farooq, Jacqueline O Hur, John Hur
PURPOSE: Total hip arthroplasty (THA) using the direct anterior approach (DAA) is known to have a learning curve. The purpose of this study was to review cases where surgery was performed by an arthroplasty surgeon transitioning from the posterior approach (PA) to the DAA. We hypothesized similar complication rates and improvements in surgical duration over time. MATERIALS AND METHODS: A review of 2,452 consecutive primary THAs was conducted. Surgical duration, length of stay (LOS), surgical complications, decrease in postoperative day (POD) 1 hemoglobin, transfusion rates, POD 0 and POD 1 pain scores, incision length, leg length discrepancy (LLD), and radiographic cup position were recorded...
December 2022: Hip & Pelvis
https://read.qxmd.com/read/35992024/influence-of-less-invasive-hip-preservation-surgery-on-subsequent-hip-arthroplasty-for-osteonecrosis-of-the-femoral-head
#12
REVIEW
Liang Mo, Jianxiong Li, Zhangzheng Wang, Fayi Huang, Pengfei Xin, Chi Zhou, Wei He, Yuhao Liu
The purpose of this study was to evaluate the outcomes of total hip arthroplasty (THA) following less invasive hip-preserving procedures (LIHPs) and present a critical overview of the literature to aid in better result interpretation. The search time was from the establishment of the database to September 2021, and the outcome indicators were extracted and analyzed by Cochrane Collaboration Review Manager software (RevMan version 5.4). Finally, 10 articles were included in this meta-analysis by searching Chinese databases and English databases...
August 2022: Journal of Hip Preservation Surgery
https://read.qxmd.com/read/35846262/improving-acetabular-component-positioning-in-total-hip-arthroplasty-a-cadaveric-study-of-an-inertial-navigation-tool-and-a-novel-registration-method
#13
JOURNAL ARTICLE
Jobe Shatrov, Daniel Marsden-Jones, Matt Lyons, William L Walter
Background: Incorrect acetabular component positioning in total hip arthroplasty (THA) has been associated with poor outcomes. Computer-assisted hip arthroplasty increases accuracy and consistency of cup positioning compared to conventional methods. Traditional navigation units have been associated with problems such as bulkiness of equipment and reproducibility of anatomical landmarks, particularly in obese patients or the lateral position. Purpose : We sought to evaluate the accuracy of a novel miniature inertial measurement system, the Navbit Sprint navigation device (Navbit, Sydney, Australia), to navigate acetabular component positioning in both the supine and lateral decubitus positions...
August 2022: HSS Journal: the Musculoskeletal Journal of Hospital for Special Surgery
https://read.qxmd.com/read/35800129/the-wear-rate-and-survivorship-in-total-hip-arthroplasty-using-a-third-generation-ceramic-head-on-a-conventional-polyethylene-liner-a-minimum-of-15-year-follow-up
#14
JOURNAL ARTICLE
Bum-Jin Shim, Sung-Jin Park, Chan Ho Park
Purpose: The purpose of this study was to evaluate the wear and survival rates of third-generation ceramic heads on a conventional ultra-high molecular weight polyethylene liner. Materials and Methods: A total of 160 hips (147 patients with a mean age of 55.9 years) who underwent total hip arthroplasty using the third-generation ceramic head on a conventional polyethylene liner from March 1998 to August 2003 were reviewed retrospectively. Evaluation of the wear rate for 56 hips (49 patients) followed-up for at least 15 years was performed using the PolyWare program version 8 (Draftware Developers, USA)...
June 2022: Hip & Pelvis
https://read.qxmd.com/read/35711111/reliability-and-validity-of-standing-lateral-radiograph-method-for-measuring-acetabular-component-version-a-modified-cross-table-lateral-radiograph-method
#15
JOURNAL ARTICLE
Wenhui Zhang, Jie Xu, Deng Li, Hao Sun, Zhiqing Cai, Meiyi Chen, Ruofan Ma
OBJECTIVES: To investigate the effect of the X-ray incidence angle on cup version measurements and the reliability and validity of standing lateral (SL) radiography for measuring cup versions. METHODS: Cup versions under different X-ray incidence angles were investigated by the 3D simulation analysis. Ninety-three patients, who underwent primary total hip arthroplasty (THA) with postoperative SL radiographs and CT scans between April 2020 and December 2021, were retrospectively analyzed...
August 2022: Orthopaedic Surgery
https://read.qxmd.com/read/35504896/dislocation-risk-after-robotic-arm-assisted-total-hip-arthroplasty-a-comparison-of-anterior-lateral-and-posterolateral-approaches
#16
JOURNAL ARTICLE
Andrea Marcovigi, Dario Sandoni, Luigi Ciampalini, Piergiuseppe Perazzini, Francesco Zambianchi, William J Hozack, Fabio Catani
AIMS: Dislocation is a major cause of early failure after THA and is highly influenced by surgical approach and component positioning. Robotic-arm assisted arthroplasty has been developed in an attempt to improve component positioning and reduce postoperative complications.The purpose of this study was to compare the rate of dislocation after robotic total hip arthroplasty through 3 different surgical approaches. MATERIALS AND METHODS: All patients who had undergone robotic arm-assisted THA at 3 centres between 2014 and 2019 were reviewed...
May 3, 2022: Hip International: the Journal of Clinical and Experimental Research on Hip Pathology and Therapy
https://read.qxmd.com/read/35073513/current-concepts-in-hip-spine-relationships-making-them-practical-for-total-hip-arthroplasty
#17
REVIEW
Luigi Zagra, Francesco Benazzo, Dante Dallari, Francesco Falez, Giuseppe Solarino, Rocco D'Apolito, Claudio Carlo Castelli
Hip, spine, and pelvis move in coordination with one another during activity, forming the lumbopelvic complex (LPC). These movements are characterized by the spinopelvic parameters sacral slope, pelvic tilt, and pelvic incidence, which define a patient's morphotype. LPC kinematics may be classified by various systems, the most comprehensive of which is the Bordeaux Classification. Hip-spine relationships in total hip arthroplasty (THA) may influence impingement, dislocation, and edge loading. Historical 'safe zones' may not apply to patients with impaired spinopelvic mobility; adjustment of cup inclination and version and stem version may be necessary to achieve functional orientation and avert complications...
January 11, 2022: EFORT Open Reviews
https://read.qxmd.com/read/35039021/ceramic-on-ceramic-versus-ceramic-on-polyethylene-in-total-hip-arthroplasty-a-comparative-study-at-a-minimum-of-13-years-follow-up
#18
JOURNAL ARTICLE
Malerba Giuseppe, Basilico Mattia, Bonfiglio Nadia, Vitiello Raffaele, Ruberto Pasquale, D' Adamio Stefano, Sirgiovanni Mattia, De Santis Vincenzo, Maccauro Giulio
BACKGROUND: Nowadays hip replacement is one of the most successful surgery in terms of clinical outcome and patient's satisfaction. Therefore, the choice of biomaterials in hip replacement is increasingly important with the aim of obtaining a long-term satisfaction of patient and a greater survivorship of the implants. Ceramic-on-polyethylene (COP) and ceramic-on-ceramic (CoC) bearings are two common coupling used in total hip arthroplasty. The aim of this retrospective study was to compare clinical and radiological outcomes between patients treated using CoC and CoP THA at a mean follow-up of 15 years...
January 17, 2022: BMC Musculoskeletal Disorders
https://read.qxmd.com/read/34824723/acetabular-and-femoral-component-positioning-using-direct-anterior-approach-versus-posterior-approach-in-total-hip-arthroplasty
#19
JOURNAL ARTICLE
Tarun Goyal, Arghya Kundu Choudhury, Souvik Paul, Tushar Gupta, Lakshmana Das
Purpose: Direct anterior approach (DAA) has recently become popular in total hip arthroplasty (THA). However, irrespective of the surgical approach used, component malposition is an important factor affecting function and complications after THA. This study aims to compare component positioning on the femoral and acetabular side between DAA and posterior approach (PA) to the hip joint. We hypothesized that the two approaches are similar in terms of component positioning. Methods: We prospectively studied 50 patients, matched according to age, sex, and body mass index, undergoing THA, divided non-randomly into 2 groups...
October 2021: Indian Journal of Orthopaedics
https://read.qxmd.com/read/34814900/paradoxical-spinopelvic-motion-does-global-balance-influence-spinopelvic-motion-in-total-hip-arthroplasty
#20
JOURNAL ARTICLE
Yu-Hsien Lin, Yu-Tsung Lin, Kun-Hui Chen, Chien-Chou Pan, Cheng-Min Shih, Cheng-Hung Lee
BACKGROUND: Recent research has proposed a classification of spinopelvic stiffness according to pelvic spatial orientation for risk stratification in patients who undergo total hip arthroplasty (THA). However, the influence of global alignment was not investigated, and this study evaluated the effect of global balance (sagittal vertical axis [SVA]) on spinopelvic motion. METHODS: We conducted a retrospective review of consecutive primary THA patients. We measured SVA, spinopelvic parameters (pelvic tilt [PT], pelvic incidence, and sacral slope), thoracic kyphosis (TK), lumbar lordosis (LL), proximal femur angle (PFA), and cup version using functional radiographs of patients in the standing and upright sitting positions...
November 23, 2021: BMC Musculoskeletal Disorders
keyword
keyword
163059
1
2
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.