https://read.qxmd.com/read/38767436/a-prospective-study-of-the-diagnostic-performance-of-photon-counting-ct-compared-with-mri-in-the-characterization-of-renal-masses
#1
JOURNAL ARTICLE
Fatemeh Homayounieh, Nikhil Gopal, Fatemeh Dehghani Firouzabadi, Pooyan Sahbaee, Pouria Yazdian, Moozhan Nikpanah, Michael Do, Muyang Wang, Rabindra Gautam, Mark W Ball, William F Pritchard, Elizabeth C Jones, Han Wen, W Marston Linehan, Evrim B Turkbey, Ashkan A Malayeri
OBJECTIVES: The aim of this study was to assess the interreader reliability and per-RCC sensitivity of high-resolution photon-counting computed tomography (PCCT) in the detection and characterization of renal masses in comparison to MRI. MATERIALS AND METHODS: This prospective study included 24 adult patients (mean age, 52 ± 14 years; 14 females) who underwent PCCT (using an investigational whole-body CT scanner) and abdominal MRI within a 3-month time interval and underwent surgical resection (partial or radical nephrectomy) with histopathology (n = 70 lesions)...
May 21, 2024: Investigative Radiology
https://read.qxmd.com/read/38747489/mr-safety-of-inductively-coupled-and-conventional-intraoral-coils
#2
JOURNAL ARTICLE
Agazi Samuel Tesfai, Simon Reiss, Thomas Lottner, Michael Bock, Ali Caglar Özen
PURPOSE: Intraoral coils (IOCs) in magnetic resonance imaging (MRI) significantly improve the signal-to-noise ratio compared with conventional extraoral coils. To assess the safety of IOCs, we propose a 2-step procedure to evaluate radiofrequency-induced heating of IOCs and compare maximum temperature increases in 3 different types of IOCs. METHODS: The 2-step safety assessment consists of electric field measurements and simulations to identify local hotspots followed by temperature measurements during MRI...
May 15, 2024: Investigative Radiology
https://read.qxmd.com/read/38742928/countering-calcium-blooming-with-personalized-contrast-media-injection-protocols-the-1-2-3-rule-for-photon-counting-detector-ccta
#3
JOURNAL ARTICLE
Michael C McDermott, Thomas Sartoretti, Lion Stammen, Bibi Martens, Gregor Jost, Hubertus Pietsch, Ralf Gutjahr, Bernhard Schmidt, Thomas G Flohr, Hatem Alkadhi, Joachim E Wildberger
OBJECTIVE: Photon-counting detector computed tomography (PCD-CT) enables spectral data acquisition of CT angiographies allowing for reconstruction of virtual monoenergetic images (VMIs) in routine practice. Specifically, it has potential to reduce the blooming artifacts associated with densely calcified plaques. However, calcium blooming and iodine attenuation are inversely affected by energy level (keV) of the VMIs, creating a challenge for contrast media (CM) injection protocol optimization...
May 15, 2024: Investigative Radiology
https://read.qxmd.com/read/38709665/postoperative-extremity-tomosynthesis-a-superimposition-free-alternative-to-standard-radiography
#4
JOURNAL ARTICLE
Jan-Peter Grunz, Andreas Steven Kunz, Mila Marie Paul, Karsten Sebastian Luetkens, Henner Huflage, Nora Conrads, Süleyman Ergün, Thomas Weber, Magdalena Herbst, Sophia Herold, Thorsten Alexander Bley, Theresa Sophie Patzer
RATIONALE AND OBJECTIVES: This study investigates the performance of tomosynthesis in the presence of osteosynthetic implants, aiming to overcome superimposition-induced limitations in conventional radiograms. MATERIALS AND METHODS: After surgical fracture induction and subsequent osteosynthesis, 8 cadaveric fracture models (wrist, metacarpus, ankle, metatarsus) were scanned with the prototypical tomosynthesis mode of a multiuse x-ray system. Tomosynthesis protocols at 60, 80, and 116 kV (sweep angle 10°, 13 FPS) were compared with standard radiograms...
May 7, 2024: Investigative Radiology
https://read.qxmd.com/read/38709660/evaluation-of-the-contrast-enhancement-performance-of-gadopiclenol-for-magnetic-resonance-angiography-in-healthy-rabbits-and-pigs
#5
JOURNAL ARTICLE
Gaëlle Hugon, Hans Adriaensen, Mélody Wintrebert, Laurent Arnould, Jean-Michel Serfaty, Philippe Robert
OBJECTIVES: Unexpected accumulations of gadolinium in various organs were reported after the administration of gadolinium-based contrast agents, making desirable to reduce the dose while maintaining equivalent diagnostic performance. The aim of this study was to evaluate the contrast enhancement performance of high relaxivity gadopiclenol compared with gadoterate meglumine in abdominal contrast-enhanced magnetic resonance angiography (CE-MRA). MATERIALS AND METHODS: In a first study in healthy rabbits, axial 3D gradient echo sequences were applied at 4...
May 7, 2024: Investigative Radiology
https://read.qxmd.com/read/38687025/deep-learning-synthesis-of-white-blood-from-dark-blood-late-gadolinium-enhancement-cardiac-magnetic-resonance
#6
JOURNAL ARTICLE
Tim J M Jaspers, Bibi Martens, Richard Crawley, Lamis Jada, Sina Amirrajab, Marcel Breeuwer, Robert J Holtackers, Amedeo Chiribiri, Cian M Scannell
OBJECTIVES: Dark-blood late gadolinium enhancement (DB-LGE) cardiac magnetic resonance has been proposed as an alternative to standard white-blood LGE (WB-LGE) imaging protocols to enhance scar-to-blood contrast without compromising scar-to-myocardium contrast. In practice, both DB and WB contrasts may have clinical utility, but acquiring both has the drawback of additional acquisition time. The aim of this study was to develop and evaluate a deep learning method to generate synthetic WB-LGE images from DB-LGE, allowing the assessment of both contrasts without additional scan time...
May 1, 2024: Investigative Radiology
https://read.qxmd.com/read/38652067/machine-learning-based-perivascular-space-volumetry-in-alzheimer-disease
#7
JOURNAL ARTICLE
Katerina Deike, Andreas Decker, Paul Scheyhing, Julia Harten, Nadine Zimmermann, Daniel Paech, Oliver Peters, Silka D Freiesleben, Luisa-Sophie Schneider, Lukas Preis, Josef Priller, Eike Spruth, Slawek Altenstein, Andrea Lohse, Klaus Fliessbach, Okka Kimmich, Jens Wiltfang, Claudia Bartels, Niels Hansen, Frank Jessen, Ayda Rostamzadeh, Emrah Düzel, Wenzel Glanz, Enise I Incesoy, Michaela Butryn, Katharina Buerger, Daniel Janowitz, Michael Ewers, Robert Perneczky, Boris-Stephan Rauchmann, Stefan Teipel, Ingo Kilimann, Doreen Goerss, Christoph Laske, Matthias H Munk, Annika Spottke, Nina Roy, Michael Wagner, Sandra Roeske, Michael T Heneka, Frederic Brosseron, Alfredo Ramirez, Laura Dobisch, Steffen Wolfsgruber, Luca Kleineidam, Renat Yakupov, Melina Stark, Matthias C Schmid, Moritz Berger, Stefan Hetzer, Peter Dechent, Klaus Scheffler, Gabor C Petzold, Anja Schneider, Alexander Effland, Alexander Radbruch
OBJECTIVES: Impaired perivascular clearance has been suggested as a contributing factor to the pathogenesis of Alzheimer disease (AD). However, it remains unresolved when the anatomy of the perivascular space (PVS) is altered during AD progression. Therefore, this study investigates the association between PVS volume and AD progression in cognitively unimpaired (CU) individuals, both with and without subjective cognitive decline (SCD), and in those clinically diagnosed with mild cognitive impairment (MCI) or mild AD...
April 23, 2024: Investigative Radiology
https://read.qxmd.com/read/38597586/toward-precision-diagnosis-machine-learning-in-identifying-malignant-orbital-tumors-with-multiparametric-3-t-mri
#8
JOURNAL ARTICLE
Emma O'Shaughnessy, Lucile Senicourt, Natasha Mambour, Julien Savatovsky, Loïc Duron, Augustin Lecler
BACKGROUND: Orbital tumors present a diagnostic challenge due to their varied locations and histopathological differences. Although recent advancements in imaging have improved diagnosis, classification remains a challenge. The integration of artificial intelligence in radiology and ophthalmology has demonstrated promising outcomes. PURPOSE: This study aimed to evaluate the performance of machine learning models in accurately distinguishing malignant orbital tumors from benign ones using multiparametric 3 T magnetic resonance imaging (MRI) data...
April 11, 2024: Investigative Radiology
https://read.qxmd.com/read/38598670/quantifying-tendon-degeneration-using-magic-angle-insensitive-ultra-short-echo-time-magnetization-transfer-a-phantom-study-in-bovine-tendons
#9
JOURNAL ARTICLE
Georg C Feuerriegel, Adrian A Marth, Sophia S Goller, Monika Hilbe, Stefan Sommer, Reto Sutter
OBJECTIVES: The aim of this study was to qualitatively and quantitatively assess changes in bovine flexor tendons before and after collagen degradation and at different angles in relation to the static B0 field using 3-dimensional ultra-short echo time (UTE) magnetization transfer (MT) imaging within a clinically feasible acquisition time. MATERIALS AND METHODS: Eight bovine flexor tendons were examined at 3 T magnetic resonance imaging including 3-dimensional UTE MT and UTE T2* research application sequences (acquired within 4:04 and 6:38 minutes, respectively) before and after enzyme-induced degradation...
April 10, 2024: Investigative Radiology
https://read.qxmd.com/read/38598653/pathophysiologic-mapping-of-chronic-liver-diseases-with-longitudinal-multiparametric-mri-in-animal-models
#10
JOURNAL ARTICLE
Ferhan Baskaya, Teresa Lemainque, Barbara Klinkhammer, Susanne Koletnik, Saskia von Stillfried, Steven R Talbot, Peter Boor, Volkmar Schulz, Wiltrud Lederle, Fabian Kiessling
OBJECTIVES: Chronic liver diseases (CLDs) have diverse etiologies. To better classify CLDs, we explored the ability of longitudinal multiparametric MRI (magnetic resonance imaging) in depicting alterations in liver morphology, inflammation, and hepatocyte and macrophage activity in murine high-fat diet (HFD)- and carbon tetrachloride (CCl4)-induced CLD models. MATERIALS AND METHODS: Mice were either untreated, fed an HFD for 24 weeks, or injected with CCl4 for 8 weeks...
April 10, 2024: Investigative Radiology
https://read.qxmd.com/read/38595181/universal-120-kv-dual-source-ultra-high-pitch-protocol-on-the-photon-counting-ct-system-for-pediatric-abdomen-of-all-sizes-a-phantom-investigation-comparing-with-energy-integrating-ct
#11
JOURNAL ARTICLE
Wei Zhou, Donglai Huo, Lorna P Browne, Xin Zhou, Jason Weinman
OBJECTIVES: The purpose of this study is to determine if a universal 120-kV ultra-high pitch and virtual monoenergetic images (VMIs) protocol on the photon-counting computed tomography (PCCT) system can provide sufficient image quality for pediatric abdominal imaging, regardless of size, compared with protocols using a size-dependent kV and dual-source flash mode on the energy-integrating CT (EICT) system. MATERIALS AND METHODS: One solid water insert and 3 iodine (2, 5, 10 mg I/mL) inserts were attached or inserted into phantoms of variable sizes, simulating the abdomens of a newborn, 5-year-old, 10-year-old, and adult-sized pediatric patients...
April 10, 2024: Investigative Radiology
https://read.qxmd.com/read/38587357/normal-brain-and-brain-tumor-adc-changes-resulting-from-variation-of-diffusion-time-and-or-echo-time-in-pulsed-gradient-spin-echo-diffusion-imaging
#12
JOURNAL ARTICLE
Jens Johansson, Kerstin Lagerstrand, Isabella M Björkman-Burtscher, Mats Laesser, Hanna Hebelka, Stephan E Maier
OBJECTIVES: Increasing gradient performance on modern magnetic resonance imaging scanners has profoundly reduced the attainable diffusion and echo times for clinically available pulsed-gradient spin echo (PGSE) sequences. This study investigated how this may impact the measured apparent diffusion coefficient (ADC), which is considered an important diagnostic marker for differentiation between normal and abnormal brain tissue and for therapeutic follow-up. MATERIALS AND METHODS: Diffusion time and echo time dependence of the ADC were evaluated on a high-performance 3 T magnetic resonance imaging scanner...
April 9, 2024: Investigative Radiology
https://read.qxmd.com/read/38529924/image-quality-and-radiation-exposure-in-abdominal-angiography-a-head-to-head-comparison-of-conventional-detector-dose-driven-versus-contrast-to-noise-ratio-driven-exposure-control-at-various-source-to-image-receptor-distances-and-collimations-in-a-pilot-phantom
#13
JOURNAL ARTICLE
Thomas Werncke, Lena S Becker, Sabine K Maschke, Jan B Hinrichs, Timo C H Meine, Cornelia L A Dewald, Inga Brüsch, Regina Rumpel, Frank K Wacker, Bernhard C Meyer
OBJECTIVES: This phantom and animal pilot study aimed to compare image quality and radiation exposure between detector-dose-driven exposure control (DEC) and contrast-to-noise ratio (CNR)-driven exposure control (CEC) as functions of source-to-image receptor distance (SID) and collimation. MATERIALS AND METHODS: First, an iron foil simulated a guide wire in a stack of polymethyl methacrylate and aluminum plates representing patient thicknesses of 15, 25, and 35 cm...
March 27, 2024: Investigative Radiology
https://read.qxmd.com/read/38526041/tungsten-based-contrast-agent-for-photon-counting-detector-ct-angiography-in-calcified-coronaries-comparison-to-iodine-in-a-cardiovascular-phantom
#14
JOURNAL ARTICLE
Thomas Sartoretti, Michael C McDermott, Lion Stammen, Bibi Martens, Lukas J Moser, Gregor Jost, Hubertus Pietsch, Ralf Gutjahr, Tristan Nowak, Bernhard Schmidt, Thomas G Flohr, Joachim E Wildberger, Hatem Alkadhi
OBJECTIVES: Calcified plaques induce blooming artifacts in coronary computed tomography angiography (CCTA) potentially leading to inaccurate stenosis evaluation. Tungsten represents a high atomic number, experimental contrast agent with different physical properties than iodine. We explored the potential of a tungsten-based contrast agent for photon-counting detector (PCD) CCTA in heavily calcified coronary vessels. MATERIALS AND METHODS: A cardiovascular phantom exhibiting coronaries with calcified plaques was imaged on a first-generation dual-source PCD-CT...
March 25, 2024: Investigative Radiology
https://read.qxmd.com/read/38436405/addressing-the-contrast-media-recognition-challenge-a-fully-automated-machine-learning-approach-for-predicting-contrast-phases-in-ct-imaging
#15
JOURNAL ARTICLE
Giulia Baldini, René Hosch, Cynthia S Schmidt, Katarzyna Borys, Lennard Kroll, Sven Koitka, Patrizia Haubold, Obioma Pelka, Felix Nensa, Johannes Haubold
OBJECTIVES: Accurately acquiring and assigning different contrast-enhanced phases in computed tomography (CT) is relevant for clinicians and for artificial intelligence orchestration to select the most appropriate series for analysis. However, this information is commonly extracted from the CT metadata, which is often wrong. This study aimed at developing an automatic pipeline for classifying intravenous (IV) contrast phases and additionally for identifying contrast media in the gastrointestinal tract (GIT)...
March 4, 2024: Investigative Radiology
https://read.qxmd.com/read/38426761/clinical-safety-of-gadobutrol-review-of-over-25-years-of-use-exceeding-100-million-administrations
#16
JOURNAL ARTICLE
Jan Endrikat, Matthias Gutberlet, Karl-Titus Hoffmann, Laura Schöckel, Aasia Bhatti, Cornelia Harz, Jörg Barkhausen
BACKGROUND: The macrocyclic gadolinium-based contrast agent gadobutrol was introduced to the market in February 1998. Over the last 25 years, gadobutrol has been administered more than 100 million times worldwide providing a wealth of data related to safety. OBJECTIVE: The aim of this study was to perform a thorough review and status update on gadobutrol's safety. MATERIALS AND METHODS: Safety data from the clinical phase II-IV program and postmarketing surveillance were descriptively analyzed from February 1998 until December 31, 2022...
March 1, 2024: Investigative Radiology
https://read.qxmd.com/read/38426719/ai-based-measurement-of-lumbar-spinal-stenosis-on-mri-external-evaluation-of-a-fully-automated-model
#17
JOURNAL ARTICLE
Sanja Bogdanovic, Matthias Staib, Marco Schleiniger, Livio Steiner, Leonardo Schwarz, Christoph Germann, Reto Sutter, Benjamin Fritz
OBJECTIVES: The aim of this study was to clinically validate a fully automated AI model for magnetic resonance imaging (MRI)-based quantifications of lumbar spinal canal stenosis. MATERIALS AND METHODS: This retrospective study included lumbar spine MRI of 100 consecutive clinical patients (56 ± 17 years; 43 females, 57 males) performed on clinical 1.5 (51 examinations) and 3 T MRI scanners (49 examinations) with heterogeneous clinical imaging protocols. The AI model performed segmentations of the thecal sac on axial T2-weighted sequences...
March 1, 2024: Investigative Radiology
https://read.qxmd.com/read/38421679/morphological-and-quantitative-parametric-mri-follow-up-of-cartilage-changes-before-and-after-intra-articular-injection-therapy-in-patients-with-mild-to-moderate-knee-osteoarthritis-a-randomized-placebo-controlled-trial
#18
JOURNAL ARTICLE
Marcel Tschopp, Christian W A Pfirrmann, Florian Brunner, Sandro F Fucentese, Julien Galley, Christoph Stern, Reto Sutter, Sabrina Catanzaro, Nathalie Kühne, Andrea B Rosskopf
BACKGROUND: Intra-articular injections are routinely used for conservative treatment of knee osteoarthritis (OA). The detailed comparative therapeutic effects of these injections on cartilage tissue are still unclear. OBJECTIVE: The aim of this study was to detect and compare knee cartilage changes after intra-articular injection of glucocorticoid, hyaluronic acid, or platelet-rich plasma (PRP) to placebo using quantitative (T2 and T2* mapping) and morphological magnetic resonance imaging parameters in patients with mild or moderate osteoarthritis...
February 28, 2024: Investigative Radiology
https://read.qxmd.com/read/38421666/ultra-high-resolution-and-k-edge-imaging-of-prosthetic-heart-valves-with-spectral-photon-counting-ct-a-phantom-study
#19
JOURNAL ARTICLE
Sara Boccalini, Charles Mayard, Hugo Lacombe, Marjorie Villien, Salim Si-Mohamed, François Delahaye, Loic Boussel, Ricardo P J Budde, Matteo Pozzi, Philippe Douek
BACKGROUND AND PURPOSE: The contribution of cardiac computed tomography (CT) for the detection and characterization of prosthetic heart valve (PHV) complications is still limited due mainly to artifacts. Computed tomography systems equipped with photon-counting detectors (PCDs) have the potential to overcome these limitations. Therefore, the aim of the study was to compare image quality of PHV with PCD-CT and dual-energy dual-layer CT (DEDL-CT). MATERIALS AND METHODS: Two metallic and 3 biological PHVs were placed in a tube containing diluted iodinated contrast inside a thoracic phantom and scanned repeatedly at different angles on a DEDL-CT and PCD-CT...
February 28, 2024: Investigative Radiology
https://read.qxmd.com/read/37725492/quantification-of-hepatocellular-carcinoma-vascular-dynamics-with-contrast-enhanced-ultrasound-for-li-rads-implementation
#20
JOURNAL ARTICLE
Connor Krolak, Manjiri Dighe, Alicia Clark, Marissa Shumaker, Raymond Yeung, Richard G Barr, Yuko Kono, Michalakis Averkiou
OBJECTIVE: The aim of this study is to describe a comprehensive contrast-enhanced ultrasound (CEUS) imaging protocol and analysis method to implement CEUS LI-RADS (Liver Imaging Reporting and Data System) in a quantifiable manner. The methods that are validated with a prospective single-center study aim to simplify CEUS LI-RADS evaluation, remove observer bias, and potentially improve the sensitivity of CEUS LI-RADS. MATERIALS AND METHODS: This prospective single-center study enrolled patients with hepatocellular carcinoma (April 2021-June 2022; N = 31; mean age ± SD, 67 ± 6 years; 24 men/7 women)...
April 1, 2024: Investigative Radiology
journal
journal
20127
1
2
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.