We have located links that may give you full text access.
JOURNAL ARTICLE
RESEARCH SUPPORT, U.S. GOV'T, P.H.S.
The porous-coated anatomic total hip prosthesis, inserted without cement. A prospective study with a minimum of ten years of follow-up.
Journal of Bone and Joint Surgery. American Volume 1999 January
One hundred consecutive primary total hip arthroplasties performed with use of a porous-coated anatomic total hip prosthesis, fixed without cement, in ninety-one patients were followed prospectively for a minimum of ten years. At the time of the most recent follow-up, twenty patients (twenty-three hips) had died and seventy-one patients (seventy-seven hips) were living. The average age of the living patients was sixty-six years (range, thirty-two to ninety-two years), and their average Harris hip score was 84 points (range, 33 to 100 points). Twelve percent (nine) of the seventy-seven hips were found to be associated with pain in the thigh when the patients were specifically questioned by the examiner. Eleven hips were revised during the follow-up period. Only the acetabular component was revised in six hips, only the femoral component was revised in one hip, and both the femoral and the acetabular components were revised in four hips. Of the ten acetabular revisions, one was performed because of acute dissociation of the component and eight, because of a combination of polyethylene wear, osteolysis, and loosening; the tenth acetabular revision consisted of exchange of the liner and curettage and bone-grafting of the osteolytic area. Of the five femoral revisions, two were performed because of loosening and three, because of extensive osteolysis of the proximal aspect of the femur. Including the revised components, twelve acetabular components and five femoral components had radiographic evidence of aseptic loosening. Acetabular osteolysis occurred in seventeen hips. Femoral osteolysis occurred in thirty-nine hips: in the proximal aspect of thirty-one hips, in the distal aspect of four, and in both the proximal and the distal aspect of four. The durability of the femoral fixation documented in this study is especially encouraging in view of the fact that this was our initial experience with devices fixed without cement and that a so-called first-generation femoral component was used. However, the study also demonstrated that not all acetabular components fixed without cement function well over the long term and that specific design considerations (adequate initial fixation, congruency between the liner and the shell, an optimum shell-liner capturing mechanism, and a smaller femoral head) are warranted.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app