Accuracy of a new wrist cuff oscillometric blood pressure device: comparisons with intraarterial and mercury manometer measurements.

Accurate measurement of arterial blood pressure is of great importance for the diagnosis and treatment of hypertension. Because of the chronic nature of antihypertensive drug therapy, the involvement of the patient in blood pressure control is desirable. Such an involvement, however, is only feasible if simple, user-friendly, and precise blood pressure measurement devices are available. In this study we tested a new wrist cuff oscillometric blood pressure measurement device in 100 consecutive patients undergoing cardiac catheterization. Blood pressures were simultaneously taken intraarterially (axillary artery) and with a mercury manometer and stethoscope or noninvasive measurement device (OMRON R3). Intraarterial measurements were directly compared with two measurements taken in random order with either an arm cuff mercury manometer or the wrist cuff device. Systolic and diastolic blood pressure as assessed with the mercury manometer was higher, especially when compared with the intraarterial and the wrist cuff values, which were comparable. Correlations of blood pressure values with intraarterial measurement were 0.86 systolic and 0.75 diastolic (P < .01) for the wrist cuff and 0.84 systolic (P < .01) and 0.59 diastolic (P < .05) for the mercury manometer measurements. Reproducibility of both measurements was good for the wrist cuff device ([systolic/diastolic]: r = 0.94/0.92; P < .01) and the mercury manometer (r = 0.97/0.88; P < .01). Both methods overestimated high diastolic values, whereas only the wrist cuff underestimated high systolic values. Thus, the new oscillometric wrist cuff blood pressure measurement device measures arterial blood pressure with great accuracy and reproducibility. As compared with intraarterial values, the wrist cuff device overestimated high diastolic and underestimated high systolic blood pressure values. Blood pressure values as measured by the mercury manometer were higher than intraarterial values and those of the wrist cuff. Both noninvasive devices overestimated high diastolic values.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app