Accuracy of a new wrist cuff oscillometric blood pressure device: comparisons with intraarterial and mercury manometer measurements.
American Journal of Hypertension 1998 December
Accurate measurement of arterial blood pressure is of great importance for the diagnosis and treatment of hypertension. Because of the chronic nature of antihypertensive drug therapy, the involvement of the patient in blood pressure control is desirable. Such an involvement, however, is only feasible if simple, user-friendly, and precise blood pressure measurement devices are available. In this study we tested a new wrist cuff oscillometric blood pressure measurement device in 100 consecutive patients undergoing cardiac catheterization. Blood pressures were simultaneously taken intraarterially (axillary artery) and with a mercury manometer and stethoscope or noninvasive measurement device (OMRON R3). Intraarterial measurements were directly compared with two measurements taken in random order with either an arm cuff mercury manometer or the wrist cuff device. Systolic and diastolic blood pressure as assessed with the mercury manometer was higher, especially when compared with the intraarterial and the wrist cuff values, which were comparable. Correlations of blood pressure values with intraarterial measurement were 0.86 systolic and 0.75 diastolic (P < .01) for the wrist cuff and 0.84 systolic (P < .01) and 0.59 diastolic (P < .05) for the mercury manometer measurements. Reproducibility of both measurements was good for the wrist cuff device ([systolic/diastolic]: r = 0.94/0.92; P < .01) and the mercury manometer (r = 0.97/0.88; P < .01). Both methods overestimated high diastolic values, whereas only the wrist cuff underestimated high systolic values. Thus, the new oscillometric wrist cuff blood pressure measurement device measures arterial blood pressure with great accuracy and reproducibility. As compared with intraarterial values, the wrist cuff device overestimated high diastolic and underestimated high systolic blood pressure values. Blood pressure values as measured by the mercury manometer were higher than intraarterial values and those of the wrist cuff. Both noninvasive devices overestimated high diastolic values.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
The Effect of Albumin Administration in Critically Ill Patients: A Retrospective Single-Center Analysis.Critical Care Medicine 2024 Februrary 8
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app