Journal Article
Review
Add like
Add dislike
Add to saved papers

Continuous cardiac output and mixed venous oxygen saturation monitoring.

Continuous assessment of cardiac output and SVO2 in the critically ill may be helpful in both the monitoring variations in the patient's cardiovascular state and in determining the efficacy of therapy. Commercially available continuous cardiac output (CCO) monitoring systems are based on the pulsed warm thermodilution technique. In vitro validation studies have demonstrated that this method provides higher accuracy and greater resistance to thermal noise than standard bolus thermodilution techniques. Numerous clinical studies comparing bolus with continuous thermodilution techniques have shown this technique similarly accurate to track each other and to have negligible bias between them. The comparison between continuous thermal and other cardiac output methods also demonstrates good precision of the continuous thermal technique. Accuracy of continuous oximetry monitoring using reflectance oximetry via fiberoptics has been assessed both in vitro and in vivo. Most of the studies testing agreement between continuous SVO2 measurements and pulmonary arterial blood samples measured by standard oximetry have shown good correlation. Continuous SVO2 monitoring is often used in the management of critically ill patients. The most recently designed pulmonary artery catheters are now able to simultaneously measure either SVO2 and CCO or SVO2 and right ventricular ejection fraction. This ability to view simultaneous trends of SVO2 and right ventricular performance parameters will probably allow the clinician to graphically see the impact of volume loading or inotropic therapy over time, as well as the influence of multiple factors, including right ventricular dysfunction, on SVO2. However, the cost-effectiveness of new pulmonary artery catheters application remains still questionable because no established utility or therapeutic guidelines are available.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app