CLINICAL TRIAL
JOURNAL ARTICLE
RANDOMIZED CONTROLLED TRIAL
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Use of octyl-2-cyanoacrylate for skin closure in facial plastic surgery.

Octyl-2-cyanoacrylate is a long carbon chain cyanoacrylate derivative that is stronger and more pliable than its shorter chain derivatives. One hundred and eleven patients underwent elective surgical procedures by the same surgeon using either octyl-2-cyanoacrylate or sutures for skin closure at the University of Illinois at Chicago. Most patients underwent excision of benign skin lesions with a mean wound size of 112 mm3. Patients were randomized into either control (vertical mattress suture closure) or test groups (closure with octyl-2-cyanoacrylate). Surgical judgment was used to determine which wounds in each group required application of subcutaneous sutures to relieve tension and aid in skin edge eversion. Generally, full-thickness (through dermis) wounds larger than 1 cm3 required the use of subcutaneous sutures. The time required to close the epidermis with suture (mean, 3 minutes and 47 seconds) was about four times that of octyl-2-cyanoacrylate (mean, 55 seconds). Wounds were evaluated at 5 to 7 days for infection, wound dehiscence, or tissue reaction, and at 90 days using the modified Hollander wound evaluation scale. At 1 year, photographs of the wounds were evaluated by two facial plastic surgeons that graded the cosmetic outcome using a previously validated visual analog scale. There were no instances of wound dehiscence, hematoma, or infection in either group. Results of wound evaluation at 90 days determined by the modified Hollander scal revealed equivalent cosmetic results in both groups. Results of the visual analog scale ratings showed scores of 21.7 +/- 16.3 for the 49 patients treated with octyl-2-cyanoacrylate and 29.2 +/- 17.7 for the 51 control patients treated with sutures. The lower visual analog scale score represented a superior cosmetic outcome at 1 year with the octyl-2-cyanoacrylate as compared with sutures. This difference is statistically significant at p = 0.03. Additionally, patient satisfaction was very high in the group treated with octyl-2-cyanoacrylate.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Group 7SearchHeart failure treatmentPapersTopicsCollectionsEffects of Sodium-Glucose Cotransporter 2 Inhibitors for the Treatment of Patients With Heart Failure Importance: Only 1 class of glucose-lowering agents-sodium-glucose cotransporter 2 (SGLT2) inhibitors-has been reported to decrease the risk of cardiovascular events primarily by reducingSeptember 1, 2017: JAMA CardiologyAssociations of albuminuria in patients with chronic heart failure: findings in the ALiskiren Observation of heart Failure Treatment study.CONCLUSIONS: Increased UACR is common in patients with heart failure, including non-diabetics. Urinary albumin creatininineJul, 2011: European Journal of Heart FailureRandomized Controlled TrialEffects of Liraglutide on Clinical Stability Among Patients With Advanced Heart Failure and Reduced Ejection Fraction: A Randomized Clinical Trial.Review

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app