Does umbilical vein catheterization to exchange transfusion lead to portal vein thrombosis?

UNLABELLED: The aetiopathology of extrahepatic portal vein obstruction is unknown. In retrospective studies, umbilical vein cannulation and sepsis have been alleged to cause portal thrombosis. This prospective study was undertaken to detect whether thrombosis and consequent obstruction of the splenoportal venous system develops after umbilical vein catheterization for exchange transfusion in newborns using Doppler ultrasound. Forty children (M = 24; F = 16) who had undergone exchange transfusion for hyperbilirubinaemia were studied at school age. Maximal duration of the venous umbilical cannulation was 120 min and sepsis did not occur. Clinical, biological and sonographic examinations were normal, except in 3 children. In 2 the left branch of portal vein could not be identified (normal variant).

CONCLUSION: Our results show that, in these children, umbilical vein catheterization did not lead to development of portal vein thrombosis. However, when other risk factors such as umbilical infection, traumatic catheterization are associated, children should be screened for obstruction of the portal vein.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app