We have located links that may give you full text access.
Journal Article
Research Support, Non-U.S. Gov't
Unplanned tracheal extubation outside the operating room: a quality improvement audit of hemodynamic and tracheal airway complications associated with emergency tracheal reintubation.
Anesthesia and Analgesia 1998 June
UNLABELLED: The incidence of hemodynamic and airway complications associated with tracheal reintubation after an unplanned extubation has not been established. Patients whose tracheas were emergently intubated outside the operating room were reviewed over a 27-mo period via a quality improvement vehicle to evaluate hemodynamic and airway complications. Data from a subset of patients (n = 57) who underwent tracheal reintubation after unplanned (self-) extubation were collected for analysis. Of the reintubations, 93% took place within 2 h of self-extubation. Of the patients, 72% had hemodynamic alterations and/or airway-related complications, including hypotension (35%), tachycardia (30%), hypertension (14%), multiple laryngoscopic attempts (22%), difficult laryngoscopy (16%), difficult intubations (14%), hypoxemia (14%), and esophageal intubation (14%). In addition, one surgical airway and one case of "cannot ventilate, cannot intubate" leading to cardiac arrest and death were recorded. These findings suggest that patients requiring reintubation will likely do so soon after self-extubation and that reintubation can be fraught with significant hemodynamic and airway complications. Less than one third of patients undergo a mishap-free reintubation. Strategies to decrease the self-extubation rate in the intensive care unit are needed to improve patient safety and to lessen the potential impact of emergency airway management.
IMPLICATIONS: Self-extubation by patients requiring mechanical ventilation can be life-threatening, and replacing the breathing tube often leads to hemodynamic and airway complications. Using this quality improvement audit, 57 self-extubating patients and the complications associated with replacing the breathing tube, which are numerous and can lead to significant morbidity and mortality, were analyzed.
IMPLICATIONS: Self-extubation by patients requiring mechanical ventilation can be life-threatening, and replacing the breathing tube often leads to hemodynamic and airway complications. Using this quality improvement audit, 57 self-extubating patients and the complications associated with replacing the breathing tube, which are numerous and can lead to significant morbidity and mortality, were analyzed.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app