We have located links that may give you full text access.
Forecasting of hydrophilic contact lens tolerance by means of tear ferning test.
BACKGROUND: The ability of the tear ferning test to predict future hydrophilic contact lens tolerance was studied.
METHODS: The tear ferning test (TFT) was performed on one randomly chosen eye of each of the 116 subjects who came to our contact lens clinic for hydrophilic contact lens application. The TFT was performed at the time of enrollment (TO) and then 1 month (T1), 3 months (T2) and 6 months (T3) after contact lens fitting. The specificity and the sensitivity of the TFT in identifying future contact lens tolerance was then studied. The statistical significance of the differences in behavior through the study period among the subjects with different pre-fitting TFT results was evaluated by means of survival curves.
RESULTS: When only type I ferning was considered as a marker of good tear film conditions, the ability of the TFT to forecast contact lens tolerance had 78.95% sensitivity, 78.35% specificity and 78.45% diagnostic precision. The TFT showed sensitivity of 100%, specificity of 86.6% and diagnostic precision of 97.4% when performed after 1 month of contact lens wearing (T1). Survival curve analysis showed a statistically significant difference in behavior between the group of subjects with pre-fitting ferning type I and the other three groups (P < 0.001).
CONCLUSION: The TFT appears to have good sensitivity and specific for prediction of contact lens tolerance in a clinical setting.
METHODS: The tear ferning test (TFT) was performed on one randomly chosen eye of each of the 116 subjects who came to our contact lens clinic for hydrophilic contact lens application. The TFT was performed at the time of enrollment (TO) and then 1 month (T1), 3 months (T2) and 6 months (T3) after contact lens fitting. The specificity and the sensitivity of the TFT in identifying future contact lens tolerance was then studied. The statistical significance of the differences in behavior through the study period among the subjects with different pre-fitting TFT results was evaluated by means of survival curves.
RESULTS: When only type I ferning was considered as a marker of good tear film conditions, the ability of the TFT to forecast contact lens tolerance had 78.95% sensitivity, 78.35% specificity and 78.45% diagnostic precision. The TFT showed sensitivity of 100%, specificity of 86.6% and diagnostic precision of 97.4% when performed after 1 month of contact lens wearing (T1). Survival curve analysis showed a statistically significant difference in behavior between the group of subjects with pre-fitting ferning type I and the other three groups (P < 0.001).
CONCLUSION: The TFT appears to have good sensitivity and specific for prediction of contact lens tolerance in a clinical setting.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
Perioperative echocardiographic strain analysis: what anesthesiologists should know.Canadian Journal of Anaesthesia 2024 April 11
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app