Increasing tidal volumes and pulmonary overdistention adversely affect pulmonary vascular mechanics and cardiac output in a pediatric swine model.
Critical Care Medicine 1998 April
OBJECTIVES: In a pediatric swine model, the effects of increasing tidal volumes and the subsequent development of pulmonary overdistention on cardiopulmonary interactions were studied. The objective was to test the hypothesis that increasing tidal volumes adversely affect pulmonary vascular mechanics and cardiac output. An additional goal was to determine whether the effects of pulmonary overdistention are dependent on delivered tidal volume and/or positive end-expiratory pressure (PEEP, end-expiratory lung volume).
DESIGN: Prospective, randomized, controlled laboratory trial.
SETTING: University research laboratory.
SUBJECTS: Eleven 4- to 6-wk-old swine, weighing 8 to 12 kg.
INTERVENTIONS: Piglets with normal lungs were anesthetized, intubated, and paralyzed. After median sternotomy, pressure transducers were placed in the right ventricle, pulmonary artery, and left atrium. An ultrasonic flow probe was placed around the pulmonary artery.
MEASUREMENTS AND MAIN RESULTS: The swine were ventilated and data were collected with delivered tidal volumes of 10, 15, 20, and 25 mL/kg and PEEP settings of 5 and 10 cm H2O in a random order. Pulmonary overdistention was defined as a decrease in dynamic compliance of > or =20% when compared with a compliance measured at a baseline tidal volume of 10 mL/kg. At this baseline tidal volume, airway pressure-volume curves did not demonstrate pulmonary overdistention. Tidal volumes and airway pressures were measured by a pneumotachometer and the Pediatric Pulmonary Function Workstation. Inspiratory time (0.75 sec), FIO2 (0.3), and minute ventilation were held constant. We evaluated the pulmonary vascular and cardiac effects of the various tidal volume and PEEP settings by measuring pulmonary vascular resistance, pulmonary characteristic impedance, and cardiac output. When compared with a tidal volume of 10 mL/kg, a tidal volume of 20 mL/kg resulted in a significant decrease in dynamic compliance from 10.5 +/- 0.9 to 8.4 +/- 0.6 mL/cm H2O (p = .02) at a constant PEEP of 5 cm H2O. The decrease in dynamic compliance of 20% indicated the presence of pulmonary overdistention by definition. As the tidal volume was increased from 10 to 20 mL/kg, pulmonary vascular resistance (1351 +/- 94 vs. 2266 +/- 233 dyne x sec/cm5; p = .004) and characteristic impedance (167 +/- 12 vs. 219 +/- 22 dyne x sec/cm5; p = .02) significantly increased, while cardiac output significantly decreased (951 +/- 61 vs. 708 +/- 48 mL/min; p = .001). Each of these effects of pulmonary overdistention were further magnified when the tidal volume was increased to 25 mL/kg. The tidal volume-induced alterations in pulmonary vascular mechanics, characteristic impedance, and cardiac output occurred to a greater degree when the PEEP was increased to 10 cm H2O. Pulmonary vascular resistance and characteristic impedance were significantly increased and cardiac output significantly decreased for all tidal volumes studied at a PEEP of 10 cm H2O as compared with 5 cm H2O.
CONCLUSIONS: Increasing tidal volumes, increasing PEEP levels, and the development of pulmonary overdistention had detrimental effects on the cardiovascular system by increasing pulmonary vascular resistance and characteristic impedance while significantly decreasing cardiac output. Delivered tidal volumes of >15 mL/kg should be utilized cautiously. Careful monitoring of respiratory mechanics and cardiac function, especially in neonatal and pediatric patients, is warranted.
DESIGN: Prospective, randomized, controlled laboratory trial.
SETTING: University research laboratory.
SUBJECTS: Eleven 4- to 6-wk-old swine, weighing 8 to 12 kg.
INTERVENTIONS: Piglets with normal lungs were anesthetized, intubated, and paralyzed. After median sternotomy, pressure transducers were placed in the right ventricle, pulmonary artery, and left atrium. An ultrasonic flow probe was placed around the pulmonary artery.
MEASUREMENTS AND MAIN RESULTS: The swine were ventilated and data were collected with delivered tidal volumes of 10, 15, 20, and 25 mL/kg and PEEP settings of 5 and 10 cm H2O in a random order. Pulmonary overdistention was defined as a decrease in dynamic compliance of > or =20% when compared with a compliance measured at a baseline tidal volume of 10 mL/kg. At this baseline tidal volume, airway pressure-volume curves did not demonstrate pulmonary overdistention. Tidal volumes and airway pressures were measured by a pneumotachometer and the Pediatric Pulmonary Function Workstation. Inspiratory time (0.75 sec), FIO2 (0.3), and minute ventilation were held constant. We evaluated the pulmonary vascular and cardiac effects of the various tidal volume and PEEP settings by measuring pulmonary vascular resistance, pulmonary characteristic impedance, and cardiac output. When compared with a tidal volume of 10 mL/kg, a tidal volume of 20 mL/kg resulted in a significant decrease in dynamic compliance from 10.5 +/- 0.9 to 8.4 +/- 0.6 mL/cm H2O (p = .02) at a constant PEEP of 5 cm H2O. The decrease in dynamic compliance of 20% indicated the presence of pulmonary overdistention by definition. As the tidal volume was increased from 10 to 20 mL/kg, pulmonary vascular resistance (1351 +/- 94 vs. 2266 +/- 233 dyne x sec/cm5; p = .004) and characteristic impedance (167 +/- 12 vs. 219 +/- 22 dyne x sec/cm5; p = .02) significantly increased, while cardiac output significantly decreased (951 +/- 61 vs. 708 +/- 48 mL/min; p = .001). Each of these effects of pulmonary overdistention were further magnified when the tidal volume was increased to 25 mL/kg. The tidal volume-induced alterations in pulmonary vascular mechanics, characteristic impedance, and cardiac output occurred to a greater degree when the PEEP was increased to 10 cm H2O. Pulmonary vascular resistance and characteristic impedance were significantly increased and cardiac output significantly decreased for all tidal volumes studied at a PEEP of 10 cm H2O as compared with 5 cm H2O.
CONCLUSIONS: Increasing tidal volumes, increasing PEEP levels, and the development of pulmonary overdistention had detrimental effects on the cardiovascular system by increasing pulmonary vascular resistance and characteristic impedance while significantly decreasing cardiac output. Delivered tidal volumes of >15 mL/kg should be utilized cautiously. Careful monitoring of respiratory mechanics and cardiac function, especially in neonatal and pediatric patients, is warranted.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
Perioperative echocardiographic strain analysis: what anesthesiologists should know.Canadian Journal of Anaesthesia 2024 April 11
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app