OBJECTIVES: This study was designed to assess whether intermittent impedance of inspiratory gas exchange improves the efficiency of standard cardiopulmonary resuscitation (CPR).

BACKGROUND: Standard CPR relies on the natural elastic recoil of the chest to transiently decrease intrathoracic pressures and thereby promote venous blood return to the heart. To further enhance the negative intrathoracic pressures during the "relaxation" phase of CPR, we tested the hypothesis that intermittent impedance to inspiratory gases during standard CPR increases coronary perfusion pressures and vital organ perfusion.

METHODS: CPR was performed with a pneumatically driven automated device in a porcine model of ventricular fibrillation. Eight pigs were randomized to initially receive standard CPR alone, while seven pigs initially received standard CPR plus intermittent impedance to inspiratory gas exchange with a threshold valve set to -40 cm H2O. The compression:ventilation ratio was 5:1 and the compression rate was 80/min. At 7-min intervals the impedance threshold valve (ITV) was either added or removed from the ventilation circuit such that during the 28 min of CPR, each animal received two 7-min periods of CPR with the ITV and two 7-min periods without the valve.

RESULTS: Vital organ blood flow was significantly higher during CPR performed with the ITV than during CPR performed without the valve. Total left ventricular blood flow (mean+/-SEM) (mL/min/g) was 0.32+/-0.04 vs 0.23+/-0.03 without the ITV (p<0.05). Cerebral blood flow (mL/min/g) was 20% higher with the ITV (+ITV, 0.23+/-0.02; -ITV, 0.19+/-0.02; p<0.05). Each time the ITV was removed, there was a statistically significant decrease in the vital organ blood flow and coronary perfusion pressure.

CONCLUSIONS: Intermittent impedance to inspiratory flow of respiratory gases during standard CPR significantly improves CPR efficiency during ventricular fibrillation. These studies underscore the importance of lowering intrathoracic pressures during the relaxation phase of CPR.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Trending Papers

Remove bar
Read by QxMD icon Read
9554651
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"