We have located links that may give you full text access.
CLINICAL TRIAL
COMPARATIVE STUDY
JOURNAL ARTICLE
RANDOMIZED CONTROLLED TRIAL
Is there a better right-sided tube for one-lung ventilation? A comparison of the right-sided double-lumen tube with the single-lumen tube with right-sided enclosed bronchial blocker.
Anesthesia and Analgesia 1998 April
UNLABELLED: Anatomic variation between tracheal carina and the take-off of the right upper bronchus often makes the use of a right-sided double-lumen tube (R-DLT) or a single-lumen tube with right-sided enclosed bronchial blocker tube (R-UBB) (Univent) undesirable. This study compared the R-DLT with the R-UBB to determine whether there was any advantage of one over the other during anesthesia with one-lung ventilation (OLV) for right-sided thoracic surgeries. Forty patients requiring right lung deflation were randomly assigned to one of two groups. Twenty patients received a right-sided BronchoCath double-lumen tube, and 20 received a Univent tube with a bronchial blocker placed in the right mainstem bronchus. The following were studied: 1) time required to position each tube until satisfactory placement was achieved; 2) number of times that fiberoptic bronchoscopy was required (including one with the patient supine and one in lateral decubitus position); 3) number of malpositions after initial confirmation of tube placement; 4) time required until lung collapse; 5) surgical exposure; and 6) cost of tubes per case. No differences were found with any of these variables except that the cost of acquisition overall was greater for the R-UBB than for the R-DLT. No right upper lobe collapse was observed in the postoperative period in the chest radiograph in any of the patients studied. We conclude that either tube can be used safely and effectively for right-sided thoracic surgeries that require anesthesia for OLV.
IMPLICATIONS: In this study, right-sided double-lumen tubes were compared with the Univent with right-sided bronchial blockers. The results indicate that either tube can be used for right-sided thoracic surgery.
IMPLICATIONS: In this study, right-sided double-lumen tubes were compared with the Univent with right-sided bronchial blockers. The results indicate that either tube can be used for right-sided thoracic surgery.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app