BACKGROUND: Mechanical circulatory assistance is frequently needed in postcardiotomy patients to support the failing heart. A balloon catheter called SupraCor (ABIOMED Cardiovascular, Inc, Danvers, MA) has been developed and is similar to the existing intraaortic balloon pump with the exception of placement in the ascending versus the descending thoracic aorta. This investigation compared the effects of SupraCor versus standard intraaortic balloon pump on internal mammary artery and venous conduit bypass graft blood flow.
METHODS: Porcine total heart bypass was used to anastomose a jugular vein from the ascending aorta to a subsequently ligated left anterior descending coronary artery. The left internal mammary artery was then anastomosed to the jugular vein so each conduit perfused the same coronary vascular bed. An additional right heart bypass preparation allowed precise control of cardiac output and blood pressure, which were maintained constant throughout mechanical circulatory assistance. Electromagnetic flow probes measured flow through each bypass graft and the other conduit was atraumatically occluded.
RESULTS: The SupraCor caused a significant increase in both internal mammary artery (+70% from 35 +/- mL/min to 56 +/- 9 mL/min; p = 0.04) and venous bypass graft blood flow (+49% from 66 +/- 12 mL/min to 95 +/- 15 mL/min; p = 0.02) when compared with controls. The intraaortic balloon pump failed to alter internal mammary artery or venous bypass graft flow.
CONCLUSIONS: The results demonstrate that counterpulsation with an ascending aortic balloon significantly increases coronary bypass graft flow in both internal mammary artery and venous conduits. In contrast, counterpulsation with a descending aortic balloon did not alter coronary bypass graft flow.
METHODS: Porcine total heart bypass was used to anastomose a jugular vein from the ascending aorta to a subsequently ligated left anterior descending coronary artery. The left internal mammary artery was then anastomosed to the jugular vein so each conduit perfused the same coronary vascular bed. An additional right heart bypass preparation allowed precise control of cardiac output and blood pressure, which were maintained constant throughout mechanical circulatory assistance. Electromagnetic flow probes measured flow through each bypass graft and the other conduit was atraumatically occluded.
RESULTS: The SupraCor caused a significant increase in both internal mammary artery (+70% from 35 +/- mL/min to 56 +/- 9 mL/min; p = 0.04) and venous bypass graft blood flow (+49% from 66 +/- 12 mL/min to 95 +/- 15 mL/min; p = 0.02) when compared with controls. The intraaortic balloon pump failed to alter internal mammary artery or venous bypass graft flow.
CONCLUSIONS: The results demonstrate that counterpulsation with an ascending aortic balloon significantly increases coronary bypass graft flow in both internal mammary artery and venous conduits. In contrast, counterpulsation with a descending aortic balloon did not alter coronary bypass graft flow.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app