CLINICAL TRIAL
COMPARATIVE STUDY
CONTROLLED CLINICAL TRIAL
JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

EMT defibrillation does not increase survival from sudden cardiac death in a two-tiered urban-suburban EMS system.

OBJECTIVE: The use of automatic external defibrillators (AEDs) by EMS initial responders is widely advocated. Evidence supporting the use of AEDs is based largely on the experience of one metropolitan area, with effect on survival in many systems not yet proved. We conducted this study to determine whether the addition of AEDs to an EMS system with a response time of 4 minutes for first-responder emergency medical technicians (FREMTs) and 10 minutes for paramedics would affect survival from cardiac arrest.

METHODS: This prospective, controlled, crossover study (AED versus no AED) of consecutive cardiac arrests managed by 24 FREMT fire companies took place from 1992 to 1995 in Charlotte, North Carolina, a city of 455,000. Patients were stratified using the Utstein criteria. The primary endpoint was survival to hospital discharge among patients with bystander-witnessed arrests of cardiac origin.

RESULTS: Of the 627 patients, 243 were bystander-witnessed arrests of cardiac origin. Survival to hospital discharge was accomplished in 5 of 110 patients (4.6%; 95% confidence interval [CI] 0.6% to 8.4%) with AED compared with 7 of 133 (5.3%, 95% CI 1.5% to 9.1%) without AED (P = .8). Both groups were comparable with regard to age, gender, history of myocardial infarction, congestive heart failure or diabetes, arrest at home, bystander CPR, and whether or not ventricular fibrillation (VF) was the initial rhythm. For arrests of any cause, witnessed by bystanders or EMS personnel, with an initial rhythm of VF or ventricular tachycardia (VT), 5 of 77 (6.5%, 95% CI 1.0% to 12.0%) with AED survived compared with 8 of 105 patients (7.6%, 95% CI 2.5% to 12.7%) without AED (P = .8). Statistically significant differences were noted in race and EMS response times between the two groups, which did not affect survival.

CONCLUSION: Addition of AEDs to this EMS system did not improve survival from sudden cardiac death. The data do not support routinely equipping initial responders with AEDs as an isolated enhancement, and raise further doubt about such expenditures in similar EMS systems without first optimizing bystander CPR and EMS dispatching.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app