Fentanyl augments the blockade of the sympathetic response to incision (MAC-BAR) produced by desflurane and isoflurane: desflurane and isoflurane MAC-BAR without and with fentanyl.

Anesthesiology 1998 January
BACKGROUND: Heart rate (HR) or mean arterial blood pressure (MAP) may increase in response to incision despite the absence of a motor response. The authors hypothesized that the MAC-BAR (minimum alveolar concentration of an anesthetic that blocks adrenergic response to incision) for isoflurane would exceed that for desflurane, and that fentanyl would decrease the MAC-BAR for each anesthetic in a dose-dependent manner.

METHODS: Seventy-one patients were randomly allocated to one of six groups: desflurane or isoflurane without fentanyl or with 1.5 or 3 microg/kg fentanyl given intravenously 5 min before surgical incision. Anesthesia was induced with 2 mg/kg propofol given intravenously, and tracheal intubation facilitated with 0.1 mg/kg given intravenously. The first patient in each group received 1 MAC (end-tidal) of the inhaled anesthetic in 60% nitrous oxide (0.55 MAC), balance oxygen, maintained for at least 10 min before incision. The response was considered positive if the HR or MAP increased 15% or more. If the response was positive, the end-tidal concentration given to the next patient was 0.3 MAC greater; if the response was negative, the end-tidal concentration was 0.3 MAC less. The MAC-BAR level was calculated as the mean of four independent cross-over responses in each group.

RESULTS: Desflurane and isoflurane anesthesia with 60% nitrous oxide did not change HR (P > 0.05) and decreased MAP (P < 0.05) before incision. Plasma epinephrine and norepinephrine concentrations after anesthesia and before incision were normal in all groups. The MAC-BAR level, without fentanyl, did not differ (P > 0.05) between desflurane (1.30 +/- 0.34 MAC [mean +/- SD]) and isoflurane (1.30 +/- 0.18 MAC). Fentanyl given at 1.5 microg/kg intravenously equivalently (P > 0.05) reduced the MAC-BAR for desflurane (to 0.40 +/- 0.18 MAC; P < 0.05) and isoflurane (to 0.55 +/- 0.00 MAC; P < 0.05), but a further increase in fentanyl to 3 microg/kg caused no greater decrease in the MAC-BAR for desflurane (0.48 +/- 0.16 MAC) and isoflurane (0.40 +/- 0.30 MAC).

CONCLUSIONS: Clinically attainable doses of desflurane and isoflurane, in 60% nitrous oxide (0.55 MAC), block the cardiovascular response to surgical incision at 1.3 MAC. Fentanyl given at 1.5 microg/kg decreases the MAC-BAR for each agent with no further decrease produced by 3 microg/kg fentanyl.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app