Electrical injury from subway third rails: serious injury associated with intermediate voltage contact.
Burns 1997 September
BACKGROUND: Railway and subway-associated electrical trauma is rare and typically involves high voltage (> 20,000) arc injuries. Not all rail systems utilize such high voltage. We report 16 cases of electrical trauma due to 600 V direct contact with subway 'third' rails.
METHODS: A case series of injured patients presenting to Shriners Burns Institute, Boston or Massachusetts General Hospital between 1970 and 1995 was retrospectively analyzed.
RESULTS: A total of 16 cases was identified. Among seven subway workers, the mechanism of rail contact was unintentional by a tool, a hand or by falling; no deaths occurred. Among nine non-occupational victims, injuries involved suicide attempts, unintentional falls, or risk-taking behavior. This group suffered greater burn severity, operative procedures, and complications; three deaths occurred.
CONCLUSIONS: This is the largest report series of direct electrical trauma from a subway third rail. The high morbidity and mortality from this 600 V contact suggests that the traditional classification of low voltage (< 1000 V) exposure can be subdivided to reflect the serious and lethal potential of intermediate range exposures compared to household range exposures (0-220 V).
METHODS: A case series of injured patients presenting to Shriners Burns Institute, Boston or Massachusetts General Hospital between 1970 and 1995 was retrospectively analyzed.
RESULTS: A total of 16 cases was identified. Among seven subway workers, the mechanism of rail contact was unintentional by a tool, a hand or by falling; no deaths occurred. Among nine non-occupational victims, injuries involved suicide attempts, unintentional falls, or risk-taking behavior. This group suffered greater burn severity, operative procedures, and complications; three deaths occurred.
CONCLUSIONS: This is the largest report series of direct electrical trauma from a subway third rail. The high morbidity and mortality from this 600 V contact suggests that the traditional classification of low voltage (< 1000 V) exposure can be subdivided to reflect the serious and lethal potential of intermediate range exposures compared to household range exposures (0-220 V).
Full text links
Trending Papers
Carvedilol, probably the β-blocker of choice for everyone with cirrhosis and portal hypertension: But not so fast!Liver International : Official Journal of the International Association for the Study of the Liver 2023 June
Evidence-Based Guideline for the diagnosis and management of eosinophilic granulomatosis with polyangiitis.Nature Reviews. Rheumatology 2023 May 10
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app